Rapid Identification and Analysis of Ochratoxin-A in Food and Agricultural Soil Samples Using a Novel Semi-Automated In-Syringe Based Fast Mycotoxin Extraction (FaMEx) Technique Coupled with UHPLC-MS/MS

التفاصيل البيبلوغرافية
العنوان: Rapid Identification and Analysis of Ochratoxin-A in Food and Agricultural Soil Samples Using a Novel Semi-Automated In-Syringe Based Fast Mycotoxin Extraction (FaMEx) Technique Coupled with UHPLC-MS/MS
المؤلفون: Karthikeyan Prakasham, Swapnil Gurrani, Jen-Taie Shiea, Ming-Tsang Wu, Chia-Fang Wu, Yi-Jia Ku, Tseng-Yu Tsai, Hung-Ta Hua, Yu-Jia Lin, Po-Chin Huang, Gangadhar Andaluri, Vinoth Kumar Ponnusamy
المصدر: Molecules, Vol 28, Iss 3, p 1442 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Organic chemistry
مصطلحات موضوعية: coffee, tea, ochratoxin-A, micro-QUECHERS, in-syringe, UHPLC-MS/MS, Organic chemistry, QD241-441
الوصف: In this work, a fast mycotoxin extraction (FaMEx) technique was developed for the rapid identification and quantification of carcinogenic ochratoxin-A (OTA) in food (coffee and tea) and agricultural soil samples using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) detection. The FaMEx technique advancement is based on two plastic syringes integrated setup for rapid extraction and its subsequent controlled clean-up process. In the extraction process, a 0.25-g sample and extraction solvent were added to the first syringe barrel for the vortex-based extraction. Then, the extraction syringe was connected to a clean-up syringe (pre-packed with C18, activated carbon, and MgSO4) with a syringe filter. Afterward, the whole set-up was placed in an automated programmable mechanical set-up for controlled elution. To enhance FaMEx technology performance, the various influencing sample pretreatment parameters were optimized. Furthermore, the developed FaMEx method indicated excellent linearity (0.9998 and 0.9996 for coffee/tea and soil) with highly sensitive detection (0.30 and 0.29 ng/mL for coffee/tea and soil) and quantification limits (1.0 and 0.96 for coffee/tea and soil), which is lower than the toxicity limit compliant with the European Union regulation for OTA (5 ng/g). The method showed acceptable relative recovery (84.48 to 100.59%) with
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1420-3049
Relation: https://www.mdpi.com/1420-3049/28/3/1442; https://doaj.org/toc/1420-3049
DOI: 10.3390/molecules28031442
URL الوصول: https://doaj.org/article/4ecaaefe56094c4da7dc8ed1c3942a7c