A Quantitative Comparison of Multispectral Refraction Topography and Autorefractometer in Young Adults

التفاصيل البيبلوغرافية
العنوان: A Quantitative Comparison of Multispectral Refraction Topography and Autorefractometer in Young Adults
المؤلفون: Yunru Liao, Zhenlan Yang, Zijing Li, Rui Zeng, Jing Wang, Yichi Zhang, Yuqing Lan
المصدر: Frontiers in Medicine, Vol 8 (2021)
بيانات النشر: Frontiers Media S.A., 2021.
سنة النشر: 2021
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: consistency, multispectral refraction topography, autorefractometer, refraction, multispectral imaging, Medicine (General), R5-920
الوصف: Purpose: Purpose of this study is to evaluate the measuring consistency of central refraction between multispectral refraction topography (MRT) and autorefractometry.Methods: This was a descriptive cross-sectional study including subjects in Sun Yat-sen Memorial Hospital from September 1, 2020, to December 31, 2020, ages 20 to 35 years with a best corrected visual acuity of 20/20 or better. All patients underwent cycloplegia, and the refractive status was estimated with autorefractometer, experienced optometrist and MRT. We analyzed the central refraction of the autorefractometer and MRT. The repeatability and reproducibility of values measured using both devices were evaluated using intraclass correlation coefficients (ICCs).Results: A total of 145 subjects ages 20 to 35 (290 eyes) were enrolled. The mean central refraction of the autorefractometer was −4.69 ± 2.64 diopters (D) (range −9.50 to +4.75 D), while the mean central refraction of MRT was −4.49 ± 2.61 diopters (D) (range −8.79 to +5.02 D). Pearson correlation analysis revealed a high correlation between the two devices. The intraclass correlation coefficient (ICC) also showed high agreement. The intrarater and interrater ICC values of central refraction were more than 0.90 in both devices and conditions. At the same time, the mean central refraction of experienced optometrist was −4.74 ± 2.66 diopters (D) (range −9.50 to +4.75D). The intra-class correlation coefficient of central refraction measured by MRT and subjective refraction was 0.939.Conclusions: Results revealed that autorefractometry, experienced optometrist and MRT show high agreement in measuring central refraction. MRT could provide a potential objective method to assess peripheral refraction.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2296-858X
Relation: https://www.frontiersin.org/articles/10.3389/fmed.2021.715640/full; https://doaj.org/toc/2296-858X
DOI: 10.3389/fmed.2021.715640
URL الوصول: https://doaj.org/article/d5037af5824c425d87a00dc7fbeaf1df
رقم الأكسشن: edsdoj.5037af5824c425d87a00dc7fbeaf1df
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2296858X
DOI:10.3389/fmed.2021.715640