دورية أكاديمية

Changes in the blood indicators of experimental animals by introduction of the components based on lanthanide ions and calcium into the zone of a femoral fracture

التفاصيل البيبلوغرافية
العنوان: Changes in the blood indicators of experimental animals by introduction of the components based on lanthanide ions and calcium into the zone of a femoral fracture
المؤلفون: Ildar F. Akhtyamov, Kazan State Medical University, Kazan, Russian Federation, Darya A. Korobeynikova, Hao Zhi Han, Egor I. Sidoruk
المصدر: Гений oртопедии, Vol 26, Iss 2, Pp 228-233 (2020)
بيانات النشر: Russian Ilizarov Scientific Center for Restorative Traumatology and Orthopaedics, 2020.
سنة النشر: 2020
المجموعة: LCC:Orthopedic surgery
مصطلحات موضوعية: rat, femoral bone, hematological values, Orthopedic surgery, RD701-811
الوصف: Introduction Reduction of time to restore bone integrity remains one of the main problems in traumatology and orthopedics. To solve this problem, various kinds of components have been used, one of which are bisphosphonates. This article presents an experiment, the purpose of which was to study the effect of components based on etidronates of lanthanide or calcium on blood indicators by different ways of their introduction into the femoral fracture site in experimental animals. Materials and methods Studies were conducted on 75 male rats aged 5–6 months, weighing 300–350 g. A femoral fracture was modeled in all animals, and retrograde intramedullary osteosynthesis was performed. Animals were divided into 5 groups. Group 1 received no components; a component based on etidronates of lanthanide and calcium was introduced in group 2 through a catheter; group 3 had paraossal administration of etidronates of lanthanide and calcium; group 4 had paraossal introduction of a component based on etidronate calcium through a catheter; and group 5 had introduction of components based on etidronates and calcium. Animals received the investigated components twice in the fracture zone on days 3 and 5 after the operation, except the comparison group. Results In groups with a catheter, the most pronounced local inflammatory response was observed. Changes in hemoglobin concentration were observed in all groups, in the early (7 days) period. It was found that in rats which were injected with components containing lanthanides, the average content of hemoglobin, erythrocytes and leukocytes were identical to those of group 1. Conclusion The study revealed that the components, which include lanthanide ions do not cause negative changes in the rat blood according to hematological tests.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Russian
تدمد: 1028-4427
2542-131X
Relation: http://ilizarov-journal.com/files/2020_2_12.pdf; https://doaj.org/toc/1028-4427; https://doaj.org/toc/2542-131X
DOI: 10.18019/1028-4427-2020-26-2-228-233
URL الوصول: https://doaj.org/article/e50fe3f5f3d64a8bb1f38206daeff24d
رقم الأكسشن: edsdoj.50fe3f5f3d64a8bb1f38206daeff24d
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:10284427
2542131X
DOI:10.18019/1028-4427-2020-26-2-228-233