دورية أكاديمية

High-resolution oblique coronal MRI at optimal flexed-knee angle: a novel imaging method for enhanced anterior cruciate ligament tear diagnosis

التفاصيل البيبلوغرافية
العنوان: High-resolution oblique coronal MRI at optimal flexed-knee angle: a novel imaging method for enhanced anterior cruciate ligament tear diagnosis
المؤلفون: Can Chen, Xiao Liu, Peng Wu, Qi Liang, Song Peng, Pengzhi Hu, Yunjie Liao
المصدر: Journal of Orthopaedic Surgery and Research, Vol 19, Iss 1, Pp 1-10 (2024)
بيانات النشر: BMC, 2024.
سنة النشر: 2024
المجموعة: LCC:Orthopedic surgery
LCC:Diseases of the musculoskeletal system
مصطلحات موضوعية: Anterior cruciate ligament tear, Coronal positioning, Diagnostic performance, Flexion angle, High-resolution magnetic resonance imaging, Orthopedic surgery, RD701-811, Diseases of the musculoskeletal system, RC925-935
الوصف: Abstract Background The accuracy of traditional knee MR imaging in diagnosing anterior cruciate ligament tears, especially partial tears, is relatively low, which may lead to misdiagnosis and missed diagnosis. This study aimed to assess the diagnostic performance of a novel imaging method, high-resolution oblique coronal MRI at an optimal flexed-knee Angle, for ACL tears. Methods 50 healthy volunteers were scanned with a scan-assisted device for the optimal flexion angle of ACL. For 92 knee trauma patients selected strictly according to inclusion and exclusion criteria, conventional extended-knee scans (control group) and high-resolution oblique coronal scans based on the optimal flexed-knee angle (experimental group) were conducted. Two observers rated ACL visibility blindly on a 5-point scale. Arthroscopy-defined outcomes determined diagnostic metrics for each method and sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated. Results The average optimal flexion angle for healthy volunteers was approximately 30° (30.3° ± 5.0°). Imaging demonstrated complete visualization of the ACL in 96.7% of images in the experimental group versus 12.0% in the control group. The diagnostic indicators of the experimental group surpassed those of the control group: sensitivity (94.9% vs. 76.3%), specificity (97.0% vs. 81.8%), positive predictive value (98.2% vs. 88.2%), negative predictive value(91.4% vs. 65.9%), and accuracy (95.7% vs. 78.3%). ROC analysis indicated superior diagnostic performance in the experimental group, with an AUC of 0.945 compared with 0.776 for the control group (p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1749-799X
Relation: https://doaj.org/toc/1749-799X
DOI: 10.1186/s13018-024-04956-w
URL الوصول: https://doaj.org/article/51997e59bbab42099d4c54da1ec97af1
رقم الأكسشن: edsdoj.51997e59bbab42099d4c54da1ec97af1
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1749799X
DOI:10.1186/s13018-024-04956-w