دورية أكاديمية

Dry Laser‐Induced Graphene Fractal‐like ECG Electrodes

التفاصيل البيبلوغرافية
العنوان: Dry Laser‐Induced Graphene Fractal‐like ECG Electrodes
المؤلفون: Yann Houeix, Denice Gerardo, Francisco J. Romero, Víctor Toral, Lidia Hernandez, Almudena Rivadeneyra, Encarnación Castillo, Diego P. Morales, Noel Rodriguez
المصدر: Advanced Electronic Materials, Vol 10, Iss 7, Pp n/a-n/a (2024)
بيانات النشر: Wiley-VCH, 2024.
سنة النشر: 2024
المجموعة: LCC:Electric apparatus and materials. Electric circuits. Electric networks
LCC:Physics
مصطلحات موضوعية: dry electrodes, electrocardiogram, flexible electronics, fractal geometry, laser‐induced graphene, Electric apparatus and materials. Electric circuits. Electric networks, TK452-454.4, Physics, QC1-999
الوصف: Abstract Fractal‐like geometries applied to biosignal‐electrodes design show great potential for enhancing the signal acquisition of sensing systems. This study reports a novel approach for flexible, silver‐free, and dry fractal‐like electrodes based on Laser‐Induced Graphene (LIG) obtained through laser photothermal processing of a commercial polyimide film. This one‐step mask‐less manufacturing process enables the simple fabrication of natural and optimized fractal‐like shapes inspired by actual snowflake patterns. To ensure a reliable and standardized connection to the measurement unit, the electrodes are equipped with a snap terminal. The electrodes are structurally characterized using various techniques including Scanning Electron Microscopy (SEM), Raman spectroscopy, and X‐ray Photoelectron Spectroscopy (XPS). By benchmarking the performance of these electrodes against Ag/AgCl wet commercial electrodes and LIG electrodes shaped as commercial ones, a heart rate‐monitoring accuracy of over 96.8% is achieved, with high specificity, positive prediction, and sensitivity, surpassing the 95.8% achieved by conventional commercial electrodes. These results demonstrate the efficacy of fractal‐based designs in combination with LIG‐based transduction, offering flexible and cost‐effective electrocardiogram (ECG) electrodes with improved performance compared to traditional wet electrodes.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2199-160X
Relation: https://doaj.org/toc/2199-160X
DOI: 10.1002/aelm.202300767
URL الوصول: https://doaj.org/article/ec51fc031c4449c591f97e52ed3956ba
رقم الأكسشن: edsdoj.51fc031c4449c591f97e52ed3956ba
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2199160X
DOI:10.1002/aelm.202300767