Computed Tomography-Based Evaluation of Volume and Position Changes of the Target Region and Organs at Risk During Radiotherapy for Esophageal Cancer: A Pilot Study

التفاصيل البيبلوغرافية
العنوان: Computed Tomography-Based Evaluation of Volume and Position Changes of the Target Region and Organs at Risk During Radiotherapy for Esophageal Cancer: A Pilot Study
المؤلفون: Yi-mei Liu, Ying-lin Peng, Qi-wen Li, Guanzhu Shen, Ya-ru Ma, Mei-ning Chen, Jun Zhang, Li-rong Fu, Bo Qiu, Hui Liu, Xiao-wu Deng
المصدر: Frontiers in Oncology, Vol 11 (2021)
بيانات النشر: Frontiers Media S.A., 2021.
سنة النشر: 2021
المجموعة: LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: esophageal cancer, adaptive radiotherapy, target retraction, volume changed ratio, geometric center deviation, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: ObjectiveTo analyze changes in volume and position of target regions and organs at risk (OARs) during radiotherapy for esophageal cancer patients.MethodsOverall, 16 esophageal cancer patients who underwent radiotherapy, including 10 cases of intensity-modulated radiation therapy (IMRT) and six of three-dimensional conformal radiotherapy (3D-CRT), were enrolled. The prescription doses for the planning target volumes (PTVs) were as follows: PTV1, 64 Gy/32 fractions; and PTV2, 46 Gy/23 fractions. Repeat computed tomography (CT) was performed for patients after the 5th, 10th, 15th, 20th, and 25th fractions. Delineation of the gross tumor volume (GTV) and OAR volume was determined using five repeat CTs performed by the same physician. The target and OAR volumes and centroid positions were recorded and used to analyze volume change ratio (VCR), center displacement (ΔD), and changes in the distance from the OAR centroid positions to the planned radiotherapy isocenter (distance to isocenter, DTI) during treatment.ResultsNo patient showed significant changes in target volume (TV) after the first week of radiotherapy (five fractions). However, TV gradually decreased over the following weeks, with the rate slowing after the fourth week (40 Gy). The comparison of TV from baseline to 40 Gy (20 fractions) showed that average GTVs decreased from 130.7 ± 63.1 cc to 92.1 ± 47.2 cc, with a VCR of −29.21 ± 13.96% (p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2234-943X
Relation: https://www.frontiersin.org/articles/10.3389/fonc.2021.702400/full; https://doaj.org/toc/2234-943X
DOI: 10.3389/fonc.2021.702400
URL الوصول: https://doaj.org/article/53cdde1177284a83af9e1720cde5b4a9
رقم الأكسشن: edsdoj.53cdde1177284a83af9e1720cde5b4a9
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2234943X
DOI:10.3389/fonc.2021.702400