Artificial Intelligence Detection of Diabetic Retinopathy

التفاصيل البيبلوغرافية
العنوان: Artificial Intelligence Detection of Diabetic Retinopathy
المؤلفون: Jennifer Irene Lim, MD, Carl D. Regillo, MD, SriniVas R. Sadda, MD, Eli Ipp, MD, Malavika Bhaskaranand, PhD, Chaithanya Ramachandra, PhD, Kaushal Solanki, PhD, Harvey Dubiner, MD, Grace Levy-Clarke, MD, Richard Pesavento, MD, Mark D. Sherman, MD, Steven Silverstein, MD, Brian Kim, MD, Gerald B. Walman, MD, Barbara A. Blodi, Amitha Domalpally, Susan Reed, James Reimers, Kris Lang, Holy Cohn, Ruth Shaw, Sheila Watson, Andrew Ewen, Nancy Barrett, Maria Swift, Jeffrey Gornbein
المصدر: Ophthalmology Science, Vol 3, Iss 1, Pp 100228- (2023)
بيانات النشر: Elsevier, 2023.
سنة النشر: 2023
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: Artificial intelligence, Diabetic retinopathy, Screening, Ophthalmology, RE1-994
الوصف: Objective: To compare general ophthalmologists, retina specialists, and the EyeArt Artificial Intelligence (AI) system to the clinical reference standard for detecting more than mild diabetic retinopathy (mtmDR). Design: Prospective, pivotal, multicenter trial conducted from April 2017 to May 2018. Participants: Participants were aged ≥ 18 years who had diabetes mellitus and underwent dilated ophthalmoscopy. A total of 521 of 893 participants met these criteria and completed the study protocol. Testing: Participants underwent 2-field fundus photography (macula centered, disc centered) for the EyeArt system, dilated ophthalmoscopy, and 4-widefield stereoscopic dilated fundus photography for reference standard grading. Main Outcome Measures: For mtmDR detection, sensitivity and specificity of EyeArt gradings of 2-field, fundus photographs and ophthalmoscopy grading versus a rigorous clinical reference standard comprising Reading Center grading of 4-widefield stereoscopic dilated fundus photographs using the ETDRS severity scale. The AI system provided automatic eye-level results regarding mtmDR. Results: Overall, 521 participants (999 eyes) at 10 centers underwent dilated ophthalmoscopy: 406 by nonretina and 115 by retina specialists. Reading Center graded 207 positive and 792 eyes negative for mtmDR. Of these 999 eyes, 26 eyes were ungradable by the EyeArt system, leaving 973 eyes with both EyeArt and Reading Center gradings. Retina specialists correctly identified 22 of 37 eyes as positive (sensitivity 59.5%) and 182 of 184 eyes as negative (specificity 98.9%) for mtmDR versus the EyeArt AI system that identified 36 of 37 as positive (sensitivity 97%) and 162 of 184 eyes as negative (specificity of 88%) for mtmDR. General ophthalmologists correctly identified 35 of 170 eyes as positive (sensitivity 20.6%) and 607 of 608 eyes as negative (specificity 99.8%) for mtmDR compared with the EyeArt AI system that identified 164 of 170 as positive (sensitivity 96.5%) and 525 of 608 eyes as negative (specificity 86%) for mtmDR. Conclusions: The AI system had a higher sensitivity for detecting mtmDR than either general ophthalmologists or retina specialists compared with the clinical reference standard. It can potentially serve as a low-cost point-of-care diabetic retinopathy detection tool and help address the diabetic eye screening burden.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2666-9145
Relation: http://www.sciencedirect.com/science/article/pii/S2666914522001178; https://doaj.org/toc/2666-9145
DOI: 10.1016/j.xops.2022.100228
URL الوصول: https://doaj.org/article/54dd77e029944112a3462ee3def22765
رقم الأكسشن: edsdoj.54dd77e029944112a3462ee3def22765
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:26669145
DOI:10.1016/j.xops.2022.100228