دورية أكاديمية

Hip joint and muscle loading for persons with bilateral transfemoral/through-knee amputations: biomechanical differences between full-length articulated and foreshortened non-articulated prostheses

التفاصيل البيبلوغرافية
العنوان: Hip joint and muscle loading for persons with bilateral transfemoral/through-knee amputations: biomechanical differences between full-length articulated and foreshortened non-articulated prostheses
المؤلفون: Diana Toderita, Clement D. Favier, David P. Henson, Vasiliki Vardakastani, Kate Sherman, Alexander N. Bennett, Anthony M. J. Bull
المصدر: Journal of NeuroEngineering and Rehabilitation, Vol 20, Iss 1, Pp 1-9 (2023)
بيانات النشر: BMC, 2023.
سنة النشر: 2023
المجموعة: LCC:Neurosciences. Biological psychiatry. Neuropsychiatry
مصطلحات موضوعية: Lower limb loss, Transfemoral, Prosthesis, Joint degeneration, Muscular endurance, Neurosciences. Biological psychiatry. Neuropsychiatry, RC321-571
الوصف: Abstract Background Currently, there is little available in-depth analysis of the biomechanical effect of different prostheses on the musculoskeletal system function and residual limb internal loading for persons with bilateral transfemoral/through-knee amputations (BTF). Commercially available prostheses for BTF include full-length articulated prostheses (microprocessor-controlled prosthetic knees with dynamic response prosthetic feet) and foreshortened non-articulated stubby prostheses. This study aims to assess and compare the BTF musculoskeletal function and loading during gait with these two types of prostheses. Methods Gait data were collected from four male traumatic military BTF and four able-bodied (AB) matched controls using a 10-camera motion capture system with two force plates. BTF completed level-ground walking trials with full-length articulated and foreshortened non-articulated stubby prostheses. Inverse kinematics, inverse dynamics and musculoskeletal modelling simulations were conducted. Results Full-length articulated prostheses introduced larger stride length (by 0.5 m) and walking speed (by 0.3 m/s) than stubbies. BTF with articulated prostheses showed larger peak hip extension angles (by 10.1°), flexion moment (by 1.0 Nm/kg) and second peak hip contact force (by 3.8 bodyweight) than stubbies. There was no difference in the hip joint loading profile between BTF with stubbies and AB for one gait cycle. Full-length articulated prostheses introduced higher hip flexor muscle force impulse than stubbies. Conclusions Compared to stubbies, BTF with full-length articulated prostheses can achieve similar activity levels to persons without limb loss, but this may introduce detrimental muscle and hip joint loading, which may lead to reduced muscular endurance and joint degeneration. This study provides beneficial guidance in making informed decisions for prosthesis choice.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1743-0003
Relation: https://doaj.org/toc/1743-0003
DOI: 10.1186/s12984-023-01296-4
URL الوصول: https://doaj.org/article/552f7bebdc684ebdbaad402e40fc998a
رقم الأكسشن: edsdoj.552f7bebdc684ebdbaad402e40fc998a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17430003
DOI:10.1186/s12984-023-01296-4