دورية أكاديمية

A Comparison of Slow Infusion Intermittent Feeding versus Gravity Feeding in Preterm Infants: A Randomized Controlled Trial

التفاصيل البيبلوغرافية
العنوان: A Comparison of Slow Infusion Intermittent Feeding versus Gravity Feeding in Preterm Infants: A Randomized Controlled Trial
المؤلفون: Funda Yavanoglu Atay, Ozlem Bozkurt, Suzan Sahin, Duygu Bidev, Fatma Nur Sari, Nurdan Uras
المصدر: Children, Vol 10, Iss 8, p 1389 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Pediatrics
مصطلحات موضوعية: feeding intolerance, feeding methods, full enteral feeding, preterm, Pediatrics, RJ1-570
الوصف: Background: The transition to full enteral feeding is important for ensuring adequate growth in preterm infants. Aims: The aim of this study was to investigate the effects of two different intermittent feeding methods on the transition to full enteral feeding in preterm infants. Study design: A prospective, randomized controlled study was conducted in a neonatology and perinatology center. Subjects: Preterm infants with a gestational age between 24 + 0/7 and 31 + 6/7 were included in this study. They were divided into two groups: the SIF (slow infusion feeding) group and the IBF (intermittent bolus feeding) group. In the SIF group, feed volumes were administered over one hour using an infusion pump through an orogastric tube, with feeding occurring every three hours. The IBF group received enteral feeding using a gravity-based technique with a syringe through an orogastric tube, completed within 10 to 30 min. Outcome measures: The primary outcome was the achievement of full enteral feeding and the occurrence of feeding intolerance. Results: A total of 103 infants were enrolled in the study (50 in SIF and 53 in IBF). The time to achieve full enteral feeding did not differ significantly between the two groups (p = 0.20). The SIF group had significantly fewer occurrences in which gastric residual volume exceeded 50% (p = 0.01). Moreover, the SIF group had a significantly shorter duration of non-per-oral (NPO) status than the IBF group (p = 0.03). Conclusions: It is our contention that the use of the SIF method as an alternative feeding method is appropriate for infants with feeding intolerance and those at high risk of feeding intolerance.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2227-9067
Relation: https://www.mdpi.com/2227-9067/10/8/1389; https://doaj.org/toc/2227-9067
DOI: 10.3390/children10081389
URL الوصول: https://doaj.org/article/de581659dc494d2ba176661e089ea718
رقم الأكسشن: edsdoj.581659dc494d2ba176661e089ea718
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22279067
DOI:10.3390/children10081389