دورية أكاديمية

Introducing pulse oximetry for outpatient management of childhood pneumonia: An implementation research adopting a district implementation model in selected rural facilities in Bangladesh

التفاصيل البيبلوغرافية
العنوان: Introducing pulse oximetry for outpatient management of childhood pneumonia: An implementation research adopting a district implementation model in selected rural facilities in Bangladesh
المؤلفون: Ahmed Ehsanur Rahman, Shafiqul Ameen, Aniqa Tasnim Hossain, Janet Perkins, Sabrina Jabeen, Tamanna Majid, AFM Azim Uddin, Md. Ziaul Haque Shaikh, Muhammad Shariful Islam, Md. Jahurul Islam, Sabina Ashrafee, Husam Md. Shah Alam, Ashfia Saberin, Sabbir Ahmed, Goutom Banik, ANM Ehtesham Kabir, Anisuddin Ahmed, Mohammod Jobayer Chisti, Steve Cunningham, David H Dockrell, Harish Nair, Shams El Arifeen, Harry Campbell
المصدر: EClinicalMedicine, Vol 50, Iss , Pp 101511- (2022)
بيانات النشر: Elsevier, 2022.
سنة النشر: 2022
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: Pulse oximetry, IMCI, Pneumonia, Feasibility, Implementation research, Bangladesh, Medicine (General), R5-920
الوصف: Summary: Background: Pulse oximetry has potential for identifying hypoxaemic pneumonia and substantially reducing under-five deaths in low- and middle-income countries (LMICs) setting. However, there are few examples of introducing pulse oximetry in resource-constrained paediatric outpatient settings, such as Integrated Management of Childhood Illness (IMCI) services. Methods: The National IMCI-programme of Bangladesh designed and developed a district implementation model for introducing pulse oximetry in routine IMCI services through stakeholder engagement and demonstrated the model in Kushtia district adopting a health system strengthening approach. Between December 2020 and June 2021, two rounds of assessment were conducted based on WHO's implementation research framework and outcome variables, involving 22 IMCI service-providers and 1680 children presenting with cough/difficulty-in-breathing in 12 health facilities. The data collection procedures included structured-observations, re-assessments, interviews, and data-extraction by trained study personnel. Findings: We observed that IMCI service-providers conducted pulse oximetry assessments on all eligible children in routine outpatient settings, of which 99% of assessments were successful; 85% (95% CI 83,87) in one attempt, and 69% (95% CI 67,71) within one minute. The adherence to standard operating procedure related to pulse oximetry was 92% (95% CI 91,93), and agreement regarding identifying hypoxaemia was 97% (95% CI 96,98). The median performance-time was 36 seconds (IQR 20,75), which was longer among younger children (2-11 months: 44s, IQR 22,78; 12-59 months: 30s, IQR 18,53, p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2589-5370
Relation: http://www.sciencedirect.com/science/article/pii/S2589537022002413; https://doaj.org/toc/2589-5370
DOI: 10.1016/j.eclinm.2022.101511
URL الوصول: https://doaj.org/article/584aeaea54594cb3984b5ca938d916e8
رقم الأكسشن: edsdoj.584aeaea54594cb3984b5ca938d916e8
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:25895370
DOI:10.1016/j.eclinm.2022.101511