دورية أكاديمية

Development of an Aptamer-Based QCM-D Biosensor for the Detection of Thrombin Using Supported Lipid Bilayers as Surface Functionalization

التفاصيل البيبلوغرافية
العنوان: Development of an Aptamer-Based QCM-D Biosensor for the Detection of Thrombin Using Supported Lipid Bilayers as Surface Functionalization
المؤلفون: Anne Görner, Leyla Franz, Tuba Çanak-Ipek, Meltem Avci-Adali, Anna-Kristina Marel
المصدر: Biosensors, Vol 14, Iss 6, p 270 (2024)
بيانات النشر: MDPI AG, 2024.
سنة النشر: 2024
المجموعة: LCC:Biotechnology
مصطلحات موضوعية: aptasensor, lipid bilayer, reconstitution, QCM-D, thrombin, serum, Biotechnology, TP248.13-248.65
الوصف: Biosensors play an important role in numerous research fields. Quartz crystal microbalances with dissipation monitoring (QCM-Ds) are sensitive devices, and binding events can be observed in real-time. In combination with aptamers, they have great potential for selective and label-free detection of various targets. In this study, an alternative surface functionalization for a QCM-D-based aptasensor was developed, which mimics an artificial cell membrane and thus creates a physiologically close environment for the binding of the target to the sensor. Vesicle spreading was used to form a supported lipid bilayer (SLB) of 1-palmitoyl-2-oleoyl-glycero-3-phosphocholine (POPC) and 1,2-dipalmitoyl-sn-glycero-3-phosphethanolamine-N-(cap biotinyl) (biotin-PE). The SLB was then coated with streptavidin followed by applying a biotinylated aptamer against thrombin. SLB formation was investigated in terms of temperature and composition. Temperatures of 25 °C and below led to incomplete SLB formation, whereas a full bilayer was built at higher temperatures. We observed only a small influence of the content of biotinylated lipids in the mixture on the further binding of streptavidin. The functionalization of the sensor surface with the thrombin aptamer and the subsequent thrombin binding were investigated at different concentrations. The sensor could be reconstituted by incubation with a 5 M urea solution, which resulted in the release of the thrombin from the sensor surface. Thereafter, it was possible to rebind thrombin. Thrombin in spiked samples of human serum was successfully detected. The developed system can be easily applied to other target analytes using the desired aptamers.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2079-6374
Relation: https://www.mdpi.com/2079-6374/14/6/270; https://doaj.org/toc/2079-6374
DOI: 10.3390/bios14060270
URL الوصول: https://doaj.org/article/59dae83cbe9945578b61275c47486f1a
رقم الأكسشن: edsdoj.59dae83cbe9945578b61275c47486f1a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20796374
DOI:10.3390/bios14060270