دورية أكاديمية

In-situ electrochemical and piezogravimetric studies on the application of macrocyclic resorcinarene tetramer in the development of chemically-modified heavy metals ions detection platform in aqueous media

التفاصيل البيبلوغرافية
العنوان: In-situ electrochemical and piezogravimetric studies on the application of macrocyclic resorcinarene tetramer in the development of chemically-modified heavy metals ions detection platform in aqueous media
المؤلفون: Larbi Eddaif, Ilona Felhősi, Abdul Shaban
المصدر: Arabian Journal of Chemistry, Vol 15, Iss 5, Pp 103780- (2022)
بيانات النشر: Elsevier, 2022.
سنة النشر: 2022
المجموعة: LCC:Chemistry
مصطلحات موضوعية: Calix[4]resorcinarene, Mass-sensitive sensor, Heavy metals, Detection, Voltammetric sensors, Chemistry, QD1-999
الوصف: The new application of C-dec-9-enylcalix[4]resorcinarene (R1), as an ionophore to detect heavy metals (HMs) cations (Cd2+, Hg2+, Cu2+, and Pb2+) in the aqueous media has been investigated through the preparation of an effective mass-sensitive sensor via the exploitation of a flow-type QCM-I technique. By adjusting the ions’ amounts in model solutions over a wide range of concentrations, acquired changes in the oscillating frequency related to the loading of metal ions on the sensor’s surface were gained, and thus favorable metrological parameters displaying the lowest detection limit (LOD) associated with copper ions (10 ppb). Simultaneously, a novel voltammetric sensor was prepared by modifying gold screen-printed electrodes (SPEs) with R1. Electrochemical characterization employing CV, SWV, and EIS was carried out, showing the success of the electrode modification. Then, the experimental conditions of supporting electrolyte, pH, accumulation time, and accumulation potential were optimized to achieve an enhanced detection. The R1@SPE sensor simultaneously detected the HMs (Cd2+, Hg2+, Cu2+, Pb2+), and the lowest LOD was associated with Pb2+ (0.19 ppb). The selectivity evaluation of the electrochemical sensor was performed by studying the effect of interferences majorly present in water sources (Mg2+, Ni2+, Zn2+, Al3+, and K+) on the SWV detection signals, and it was revealed that the interfering ions did not affect the simultaneous detection of the studied HMs (RSD less than 5%), the voltammetric sensors also presented excellent repeatability and reproducibility (RSD less than 5%).
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1878-5352
Relation: http://www.sciencedirect.com/science/article/pii/S187853522200096X; https://doaj.org/toc/1878-5352
DOI: 10.1016/j.arabjc.2022.103780
URL الوصول: https://doaj.org/article/5a48bb81a312428d8c578f2c2035f8ba
رقم الأكسشن: edsdoj.5a48bb81a312428d8c578f2c2035f8ba
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:18785352
DOI:10.1016/j.arabjc.2022.103780