Analysis of Individual V˙O2max Responses during a Cardiopulmonary Exercise Test and the Verification Phase in Physically Active Women

التفاصيل البيبلوغرافية
العنوان: Analysis of Individual V˙O2max Responses during a Cardiopulmonary Exercise Test and the Verification Phase in Physically Active Women
المؤلفون: Pasquale J. Succi, Brian Benitez, Minyoung Kwak, Haley C. Bergstrom
المصدر: Journal of Functional Morphology and Kinesiology, Vol 8, Iss 3, p 124 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Diseases of the musculoskeletal system
مصطلحات موضوعية: exercise test, women, verification phase, oxygen consumption, Diseases of the musculoskeletal system, RC925-935
الوصف: This study aimed to investigate the test–retest reliability, mean, and individual responses in the measurement of maximal oxygen consumption (V˙O2max) during a cardiopulmonary exercise test (CPET) and the verification phase during cycle ergometry in women. Nine women (22 ± 2 yrs, 166.0 ± 4.5 cm, 58.6 ± 7.7 kg) completed a CPET, passively rested for 5 min, and then completed a verification phase at 90% of peak power output to determine the highest V˙O2 from the CPET (V˙O2CPET) and verification phase (V˙O2verification) on 2 separate days. Analyses included a two-way repeated measures ANOVA, intraclass correlation coefficients (ICC2,1), standard errors of the measurement (SEM), minimal differences (MD), and coefficients of variation (CoV). There was no test (test 1 versus test 2) × method (CPET vs. verification phase) interaction (p = 0.896) and no main effect for method (p = 0.459). However, test 1 (39.2 mL·kg−1·min−1) was significantly higher than test 2 (38.3 mL·kg−1·min−1) (p = 0.043). The V˙O2CPET (ICC = 0.984; CoV = 1.98%; SEM = 0.77 mL·kg−1·min−1; MD = 2.14 mL·kg−1·min−1) and V˙O2verification (ICC = 0.964; CoV = 3.30%; SEM = 1.27 mL·kg−1·min−1; MD = 3.52 mL·kg−1·min−1) demonstrated “excellent” reliability. Two subjects demonstrated a test 1 V˙O2CPET that exceeded the test 2 V˙O2CPET, and one subject demonstrated a test 1 V˙O2verification that exceeded the test 2 V˙O2verification by more than the respective CPET and verification phase MD. One subject demonstrated a V˙O2CPET that exceeded the V˙O2verification, and one subject demonstrated a V˙O2verification that exceeded the V˙O2CPET by more than the MD. These results demonstrate the importance of examining the individual responses in the measurement of the V˙O2max and suggest that the MD may be a useful threshold to quantify real individual changes in V˙O2.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2411-5142
Relation: https://www.mdpi.com/2411-5142/8/3/124; https://doaj.org/toc/2411-5142
DOI: 10.3390/jfmk8030124
URL الوصول: https://doaj.org/article/5ac0784ae9364efb9bb621717ebf54ad
رقم الأكسشن: edsdoj.5ac0784ae9364efb9bb621717ebf54ad
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:24115142
DOI:10.3390/jfmk8030124