A novel simplified method for managing inadvertent tube cut during aurolab aqueous drainage implant surgery for refractory glaucoma

التفاصيل البيبلوغرافية
العنوان: A novel simplified method for managing inadvertent tube cut during aurolab aqueous drainage implant surgery for refractory glaucoma
المؤلفون: Sachin Mungale, Paaraj Dave
المصدر: Indian Journal of Ophthalmology, Vol 67, Iss 5, Pp 694-696 (2019)
بيانات النشر: Wolters Kluwer Medknow Publications, 2019.
سنة النشر: 2019
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: Aurolab aqueous drainage implant, management, tube cut, Ophthalmology, RE1-994
الوصف: We report a novel simplified method for managing inadvertent tube cut in a patient undergoing the Aurolab aqueous drainage implant (AADI) surgery for refractory neovascular glaucoma. Tube cut occurred while applying the polyglactin ligature suture used to avoid early postoperative hypotony. The short end of the cut tube was removed and the long end reinserted into the base plate of AADI. The surgery was then completed as usual. Following the surgery, the intraocular pressure reduced to 20 mmHg which stabilized and was maintained at 10 mmHg till the last follow-up at 12 months without any glaucoma medication.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0301-4738
1998-3689
Relation: http://www.ijo.in/article.asp?issn=0301-4738;year=2019;volume=67;issue=5;spage=694;epage=696;aulast=Mungale; https://doaj.org/toc/0301-4738; https://doaj.org/toc/1998-3689
DOI: 10.4103/ijo.IJO_1708_18
URL الوصول: https://doaj.org/article/5f9e7ba6fd91455797c96d116a70edfc
رقم الأكسشن: edsdoj.5f9e7ba6fd91455797c96d116a70edfc
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:03014738
19983689
DOI:10.4103/ijo.IJO_1708_18