دورية أكاديمية

Total or subtotal replacement of tarsal plate by novel silicone plate for upper eyelid reconstruction in malignant tumors

التفاصيل البيبلوغرافية
العنوان: Total or subtotal replacement of tarsal plate by novel silicone plate for upper eyelid reconstruction in malignant tumors
المؤلفون: Salil Kumar Mandal, Basupurna Majumdar, Purban Ganguly, Stephen C Dryden, James C Fleming, Brian T Fowler
المصدر: Indian Journal of Ophthalmology, Vol 69, Iss 10, Pp 2788-2795 (2021)
بيانات النشر: Wolters Kluwer Medknow Publications, 2021.
سنة النشر: 2021
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: malignancy, reconstruction, silicone plate, tarsal plate, Ophthalmology, RE1-994
الوصف: Purpose: To evaluate the cost, safety, surgical outcome, and efficacy of modified Cutler–Beard eyelid reconstruction utilizing a novel silicone plate as a tarsal plate replacement in the repair of 60% to 100% eyelid defects following the excision of large malignant tumors. Methods: A prospective, noncomparative, interventional study of 30 eyes was done over 3 years. Fourteen patients were female, and 16 patients were male. In all the cases, a silicone plate, the synthetic, artificial tarsal plate, was utilized for a total or subtotal replacement of the tarsal plate. The created defect was measured in mm (length and width) and later expressed in percentage. Pre- and postoperative action of levator palpebrae superioris (LPS) was measured. Pre- and postoperative measurements of the margin-to-margin reflex distance (MRD1) were noted. Results: Preoperative LPS action was 1.23 ± 1.35 mm, whereas postoperative LPS actions at the end of 1 week and 18 months were 11. 8 ± 0.88 mm and 13.53 ± 0. 73 mm, respectively. Preoperative MRD1 was − 3.0 ± 1.144 mm, whereas postoperative MRD1 values at the end of 1 week and 18 months were 2.18 ± 0.27 mm and 4.16 mm ± 0.35, respectively. The mean created defect after the removal of the tumor was 87.3% ±11.10. The mean length of the silicone plate implanted in this study was 27.53 ± 2.48 mm. The follow-up period for the study participants was 18 months. Conclusion: The synthetic novel silicone plate was successful as a tarsal plate replacement. A second surgical site for ear cartilage harvesting is avoided. Cadaver transfer of Achilles tendon carries the risk of transmission of communicable diseases, for example, hepatitis B and HIV. Silicone is an inert, nonreacting, and tissue-tested material, thus eliminating the possibility of graft rejection. This material is readily available and cost-effective. The novel silicone plate is considered to be the most promising alternative material as a tarsal replacement in the future generation.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0301-4738
1998-3689
Relation: http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=10;spage=2788;epage=2795;aulast=; https://doaj.org/toc/0301-4738; https://doaj.org/toc/1998-3689
DOI: 10.4103/ijo.IJO_2822_20
URL الوصول: https://doaj.org/article/5fab2c4d224c48ce907f810b08747fde
رقم الأكسشن: edsdoj.5fab2c4d224c48ce907f810b08747fde
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:03014738
19983689
DOI:10.4103/ijo.IJO_2822_20