دورية أكاديمية

Translation, cross-cultural adaptation, and validation of the 10-item spine functional index (SFI-10) in the Brazilians with musculoskeletal spine disorders

التفاصيل البيبلوغرافية
العنوان: Translation, cross-cultural adaptation, and validation of the 10-item spine functional index (SFI-10) in the Brazilians with musculoskeletal spine disorders
المؤلفون: Devyd Weyder do Nascimento Freitas, Almir Vieira Dibai-Filho, André Pontes-Silva, Gabriel Gardhel Costa Araujo, Augusto Ribeiro de Oliveira, Plinio da Cunha Leal, Charles Philip Gabel, Cid André Fidelis-de-Paula-Gomes, Christian Emmanuel Torres Cabido
المصدر: BMC Musculoskeletal Disorders, Vol 25, Iss 1, Pp 1-10 (2024)
بيانات النشر: BMC, 2024.
سنة النشر: 2024
المجموعة: LCC:Diseases of the musculoskeletal system
مصطلحات موضوعية: Spine, Chronic pain, Patient health questionnaire, Measurement properties, Diseases of the musculoskeletal system, RC925-935
الوصف: Abstract Purpose To translate and cross-culturally adapt the Spine Functional Index (SFI) into Brazilian Portuguese (SFI-Br) in individuals with musculoskeletal spine disorders. Methods Participants (n=194) answered the Numerical Pain Rating Scale (NPRS), 36-item Short-Form Health Survey (SF-36), Roland-Morris Disability Questionnaire for General Pain (RMDQ-g), and SFI-25 incorporating the SFI-10. Structural validity, from confirmatory factor analysis (CFA), used comparative fit index (CFI), Tucker-Lewis index (TLI), root mean square error of approximation (RMSEA), and chi-square/degrees of freedom (DF). The best structure was considered from the lower values of the Akaike Information Criterion (AIC) and Bayesian Information Criterion (BIC). Construct and criterion validity used Spearman’s correlation coefficient (rho). Internal consistency used Cronbach’s alpha, reliability used intraclass correlation coefficient (ICC2,1), with ceiling and floor effects determined. Error used the standard error of the measurement (SEM) and minimal detectable change, 90% level (MDC90). Results Adequate fit indices demonstrated an unequivocal one-factor structure only for the SFI-10 (chi-square/DF 0.90, RMSEA 0.30). Test-retest reliability (ICC2,1=0.826) and internal consistency (alpha=0.864) were high. No ceiling or floor effects were observed, and error was satisfactory (SEM=9.08%, MDC90=25.15%). Conclusion The SFI Brazilian version was successfully produced with the 10-item version showing an unequivocal one-factor structure, high construct and criterion validity, reliability, internal consistency, and satisfactory error. Further research on responsiveness is required.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1471-2474
Relation: https://doaj.org/toc/1471-2474
DOI: 10.1186/s12891-024-07406-0
URL الوصول: https://doaj.org/article/d615a80889984ff185e8f5bf18cae7b9
رقم الأكسشن: edsdoj.615a80889984ff185e8f5bf18cae7b9
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14712474
DOI:10.1186/s12891-024-07406-0