دورية أكاديمية

Comparative Study on the Determination of Aflatoxin B1 in Edible Oil by Automated Immunomagnetic Beadpurification Method and Immunoaffinity Column Purification Method

التفاصيل البيبلوغرافية
العنوان: Comparative Study on the Determination of Aflatoxin B1 in Edible Oil by Automated Immunomagnetic Beadpurification Method and Immunoaffinity Column Purification Method
المؤلفون: CAO Jing-jing, LIU Ying, WANG Ya-nan, ZHAO Sheng-nan, WU Xiu-yuan, GAO Hai-jun
المصدر: Liang you shipin ke-ji, Vol 31, Iss 3, Pp 153-158 (2023)
بيانات النشر: Academy of National Food and Strategic Reserves Administration, 2023.
سنة النشر: 2023
المجموعة: LCC:Food processing and manufacture
LCC:Nutrition. Foods and food supply
مصطلحات موضوعية: automated immunomagnetic bead, immunoaffinity chromatography, ultra high liquid chromatography, aflatoxin b1, edible oil, Food processing and manufacture, TP368-456, Nutrition. Foods and food supply, TX341-641
الوصف: In this experiment the pretreatment methods of automatic immunomagnetic bead purification and immunoaffinity chromatography purification were used to quantitatively detect aflatoxin B1 in different edible oils by ultra-high performance liquid chromatography, and the accuracy, spike recovery and detection time of the two pretreatment methods were compared. The results showed that the results of automatic immunomagnetic bead purification and immunoaffinity chromatography purification for the determination of vegetable oil standard materials were 15.59 μg/kg and 14.64 μg/kg, respectively, both of which were within the standard range. Different amounts of aflatoxin B1 standard materials were added to different kinds of edible oils, and the recovery rate of spikes was between 88%~110%, and the relative standard deviation was within 5%. The Bland-Altman method was used to analyze differences between the automatic immunomagnetic bead purification method and the immunoaffinity chromatography purification method, and the results showed that differences between the two purification methods were within the acceptable range. Both methods could meet the experimental requirements in purification and enrichment of aflatoxin B1 in edible oil and can be used instead of each other. Through the comparison of detection time, automatic immunomagnetic bead purification combined with mycotoxin automatic purification instrument pretreatment method can process multiple samples at the same time, and the average purification time of one sample is less than 3 min, indicating that the treatment time is shorter, and the experimental efficiency is higher.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Chinese
تدمد: 1007-7561
Relation: http://lyspkj.ijournal.cn/lyspkj/article/abstract/20230322?st=article_issue; https://doaj.org/toc/1007-7561
DOI: 10.16210/j.cnki.1007-7561.2023.03.021
URL الوصول: https://doaj.org/article/629a178f48a548d29128f837ee260ae6
رقم الأكسشن: edsdoj.629a178f48a548d29128f837ee260ae6
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:10077561
DOI:10.16210/j.cnki.1007-7561.2023.03.021