دورية أكاديمية

Monitoring Baby Incubator Central through Internet of Things (IoT) based on Raspberry Pi Zero W with Personal Computer View

التفاصيل البيبلوغرافية
العنوان: Monitoring Baby Incubator Central through Internet of Things (IoT) based on Raspberry Pi Zero W with Personal Computer View
المؤلفون: Dila Anggraeni Puspitasari, Bambang Guruh Irianto, Lamidi Lamidi, Triwiyanto Triwiyanto
المصدر: Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics, Vol 6, Iss 1, Pp 10-15 (2024)
بيانات النشر: Jurusan Teknik Elektromedik Politeknik Kesehatan Kemenkes Surabaya, 2024.
سنة النشر: 2024
المجموعة: LCC:Medical technology
LCC:Biotechnology
مصطلحات موضوعية: baby incubators, iot, esp32, raspberry pi zero w, humidity, Medical technology, R855-855.5, Biotechnology, TP248.13-248.65
الوصف: kids born before 37 weeks of pregnancy or weighing less than 2500 grams are considered premature, whereas kids born between 38 and 40 weeks of pregnancy and between 2500 to 4000 grams are considered full-term. Given that their organ systems are still developing within the womb, premature infants find it difficult to adjust to life outside the womb. As a result, special consideration must be made. They include modifying the environment's temperature, humidity, and oxygen needs to reflect those of the mother's womb. These conditions might be replaced with a baby incubator. This tool's creation is intended to make it easier for midwives and other healthcare professionals to keep an eye on many baby incubators. The Internet of Things (IoT) system is used by this instrument to transfer data. Using three ESP32 modules that have been put together to create modules that can collect data and have that data analyzed by a server (central monitoring) Raspberry Pi Zero W. Data will be sent via Internet of Things (IoT) technology, and the website will display the data. Two tests were conducted at 32 degrees Celsius, one at 34 degrees Celsius, and one at 36 degrees Celsius for a total of five tests. This technique was developed using a form of pre-experimental, after-only study. In this configuration, researchers may only see the module reading results; incubator analyzer data are not shown. Error value 3 in monitoring at 32 degrees Celsius has a maximum error of -0.04 percent. The largest error value occurs when the temperature is set to 34 degrees Celsius, when the monitoring error value is -0.016%. Monitoring inaccuracy is at its highest, 0.01%, when the temperature is 36 degrees Celsius. The monitoring 3 error value is most at 32 degrees Celsius (-0.025 percent), followed by 34 degrees Celsius (0.031 percent), and finally 36 degrees Celsius (0.049 percent), as shown by data on noise measurements. The findings demonstrate that each measurement performed by the module still contains mistakes. Medical staff should find it easier to concurrently monitor many infant incubators thanks to this discovery.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2656-8624
Relation: https://ijeeemi.poltekkesdepkes-sby.ac.id/index.php/ijeeemi/article/view/284; https://doaj.org/toc/2656-8624
DOI: 10.35882/ijeeemi.v6i1.284
URL الوصول: https://doaj.org/article/e63266cf30ed4466bff81e63e3b0b301
رقم الأكسشن: edsdoj.63266cf30ed4466bff81e63e3b0b301
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:26568624
DOI:10.35882/ijeeemi.v6i1.284