دورية أكاديمية

Comparison of deep learning-assisted blinking analysis system and Lipiview interferometer in dry eye patients: a cross-sectional study

التفاصيل البيبلوغرافية
العنوان: Comparison of deep learning-assisted blinking analysis system and Lipiview interferometer in dry eye patients: a cross-sectional study
المؤلفون: Yueping Ren, Han Wen, Furong Bai, Binge Huang, Zhenzhen Wang, Shuwen Zhang, Yaojia Pu, Zhenmin Le, Xianhui Gong, Lei Wang, Wei Chen, Qinxiang Zheng
المصدر: Eye and Vision, Vol 11, Iss 1, Pp 1-11 (2024)
بيانات النشر: BMC, 2024.
سنة النشر: 2024
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: Incomplete blinking, Deep learning model, Dry eye disease, Ophthalmology, RE1-994
الوصف: Abstract Background Abnormal blinking pattern is associated with ocular surface diseases. However, blink is difficult to analyze due to the rapid movement of eyelids. Deep learning machine (DLM) has been proposed as an optional tool for blinking analysis, but its clinical practicability still needs to be proven. Therefore, the study aims to compare the DLM-assisted Keratograph 5M (K5M) as a novel method with the currently available Lipiview in the clinic and assess whether blinking parameters can be applied in the diagnosis of dry eye disease (DED). Methods Thirty-five DED participants and 35 normal subjects were recruited in this cross-sectional study. DED questionnaire and ocular surface signs were evaluated. Blinking parameters including number of blinks, number of incomplete blinking (IB), and IB rate were collected from the blinking videos recorded by the K5M and Lipiview. Blinking parameters were individually collected from the DLM analyzed K5M videos and Lipiview generated results. The agreement and consistency of blinking parameters were compared between the two devices. The association of blinking parameters to DED symptoms and signs were evaluated via heatmap. Results In total, 140 eyes of 70 participants were included in this study. Lipiview presented a higher number of IB and IB rate than those from DLM-assisted K5M (P ≤ 0.006). DLM-assisted K5M captured significant differences in number of blinks, number of IB and IB rate between DED and normal subjects (P ≤ 0.035). In all three parameters, DLM-assisted K5M also showed a better consistency in repeated measurements than Lipiview with higher intraclass correlation coefficients (number of blinks: 0.841 versus 0.665; number of IB: 0.750 versus 0.564; IB rate: 0.633 versus 0.589). More correlations between blinking parameters and DED symptoms and signs were found by DLM-assisted K5M. Moreover, the receiver operating characteristic analysis showed the number of IB from K5M exhibiting the highest area under curve of 0.773. Conclusions DLM-assisted K5M is a useful tool to analyze blinking videos and detect abnormal blinking patterns, especially in distinguishing DED patients from normal subjects. Large sample investigations are therefore warranted to assess its clinical utility before implementation.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2326-0254
Relation: https://doaj.org/toc/2326-0254
DOI: 10.1186/s40662-024-00373-6
URL الوصول: https://doaj.org/article/e63a05c367344b14aeb171598703cc50
رقم الأكسشن: edsdoj.63a05c367344b14aeb171598703cc50
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:23260254
DOI:10.1186/s40662-024-00373-6