دورية أكاديمية

Endoscopic Ultrasound-Guided Fine-Needle Biopsy versus Fine-Needle Aspiration in the Diagnosis of Focal Liver Lesions: Prospective Head-to-Head Comparison

التفاصيل البيبلوغرافية
العنوان: Endoscopic Ultrasound-Guided Fine-Needle Biopsy versus Fine-Needle Aspiration in the Diagnosis of Focal Liver Lesions: Prospective Head-to-Head Comparison
المؤلفون: Marcel Gheorghiu, Andrada Seicean, Sorana D. Bolboacă, Ioana Rusu, Radu Seicean, Cristina Pojoga, Ofelia Moșteanu, Zeno Sparchez
المصدر: Diagnostics, Vol 12, Iss 9, p 2214 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: fine-needle aspiration (FNA), fine-needle biopsy (FNB), focal liver lesions, endoscopic ultrasonography (EUS), diagnostic, immunohistochemistry, Medicine (General), R5-920
الوصف: Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) or fine-needle aspiration (EUS-FNA) from focal liver lesions are indicated in selected cases, but there has been no previous comparison of needle types of the same size. The aim of our study was to compare the histologic diagnostic accuracy and adequacy of cores obtained with EUS-FNB needles in contrast to those obtained with FNA needles in focal liver lesions. This prospective one-center study included patients with left lobe hepatic focal lesions with contraindications for percutaneous liver biopsy or need for EUS for concomitant lesions. Each patient had one pass of 22G EUS-FNB (Franseen) needle and one pass of 22G EUS-FNA in a crossover manner, without macroscopic on-site evaluation. Each sample was analyzed separately for histologic adequacy and diagnosis. The final diagnosis was based on histology results or on imaging follow-up in the case of negative biopsies. The EUS-FNB samples (n = 30) were found to be more adequate for histologic analysis, with more cellularity and longer tissue aggregates than the EUS-FNA samples (n = 30). The accuracy of EUS-FNB was 100%, whereas that of EUS-FNA was 86.7% (p = 0.039). No post-procedure complications were noted. The 22G EUS-FNB needle proved superior to 22G EUS-FNA in terms of tissue acquisition diagnostic accuracy and histologic adequacy in focal liver lesions.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2075-4418
Relation: https://www.mdpi.com/2075-4418/12/9/2214; https://doaj.org/toc/2075-4418
DOI: 10.3390/diagnostics12092214
URL الوصول: https://doaj.org/article/d63b6d03ea224296966224ced6494a3a
رقم الأكسشن: edsdoj.63b6d03ea224296966224ced6494a3a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20754418
DOI:10.3390/diagnostics12092214