دورية أكاديمية

Clinical Evaluation of a Newly Developed Guidewire for Pancreatobiliary Endoscopy

التفاصيل البيبلوغرافية
العنوان: Clinical Evaluation of a Newly Developed Guidewire for Pancreatobiliary Endoscopy
المؤلفون: Shigeto Ishii, Toshio Fujisawa, Hiroyuki Isayama, Shingo Asahara, Shingo Ogiwara, Hironao Okubo, Hisafumi Yamagata, Mako Ushio, Sho Takahashi, Hiroki Okawa, Wataru Yamagata, Yoshihiro Okawa, Akinori Suzuki, Yusuke Takasaki, Kazushige Ochiai, Ko Tomishima, Hiroaki Saito, Shuichiro Shiina, Takaaki Ikari
المصدر: Journal of Clinical Medicine, Vol 9, Iss 12, p 4059 (2020)
بيانات النشر: MDPI AG, 2020.
سنة النشر: 2020
المجموعة: LCC:Medicine
مصطلحات موضوعية: guidewire, common bile duct stone, malignant biliary obstruction, acute cholecystitis, Medicine
الوصف: Background: The guidewire (GW) plays an important role in pancreatobiliary endoscopy. GW quality is a critical factor in the effectiveness and efficiency of pancreatobiliary endoscopy. In this study, we evaluate a new 0.025 inch multipurpose endoscopic GW: the M-Through. Methods: Our study was a multicenter retrospective analysis. We enrolled patients who underwent endoscopic procedures using the M-Through between May 2018 and April 2020. Patients receiving the following endoscopic treatments were enrolled: common bile duct (CBD) stone extraction, endoscopic drainage for distal and hilar malignant biliary obstruction (MBO), and endoscopic drainage for acute cholecystitis. For each procedure, we examined the rate of success without GW exchange. Results: A total of 170 patients (80 with CBD stones, 60 with MBO, and 30 with cholecystitis) were enrolled. The rate of completion without GW exchange was 100% for CBD stone extraction, 83.3% for endoscopic drainage for MBO, and 43.3% for endoscopic drainage for cholecystitis. In unsuccessful cholecystitis cases with the original GW manipulator, 1 of 8 cases succeeded in the manipulator exchange. Including 6 cases who changed GW after the manipulator exchange, 11 of 16 cases succeeded in changing GW. There was significant difference in the success rate between the manipulator exchange and GW exchange (p = 0.03). The insertion of devices and stent placement after biliary cannulation (regardless of type) were almost completed with M-through. We observed no intraoperative GW-related adverse events such as perforation and bleeding due to manipulation. Conclusion: The 0.025 inch M-Through can be used for endoscopic retrograde cholangiopancreatography-related procedures efficiently and safely. Our study found high rates of success without GW exchange in all procedures except for endoscopic drainage for cholecystitis. This GW is considered (1) excellent for supportability of device insertion to remove CBD stones; (2) good for seeking the biliary malignant stricture but sometimes need the help of a hydrophilic GW; (3) suboptimal for gallbladder drainage that require a high level of seeking ability.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2077-0383
Relation: https://www.mdpi.com/2077-0383/9/12/4059; https://doaj.org/toc/2077-0383
DOI: 10.3390/jcm9124059
URL الوصول: https://doaj.org/article/ad65df1f913a48ce8910b99948e9a38f
رقم الأكسشن: edsdoj.65df1f913a48ce8910b99948e9a38f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20770383
DOI:10.3390/jcm9124059