Clinical Comparative Study for Validation of Digital Impression Reliability with the Gypsum Check: A Simple and Fast Way to Evaluate the Trueness and Accuracy of Implant-Supported Rehabilitation
العنوان: | Clinical Comparative Study for Validation of Digital Impression Reliability with the Gypsum Check: A Simple and Fast Way to Evaluate the Trueness and Accuracy of Implant-Supported Rehabilitation |
---|---|
المؤلفون: | Giuseppe Barile, Giovanni de Rosa, Paride Papadia, Giovannino Muci, Saverio Capodiferro, Massimo Corsalini |
المصدر: | Applied Sciences, Vol 13, Iss 13, p 7358 (2023) |
بيانات النشر: | MDPI AG, 2023. |
سنة النشر: | 2023 |
المجموعة: | LCC:Technology LCC:Engineering (General). Civil engineering (General) LCC:Biology (General) LCC:Physics LCC:Chemistry |
مصطلحات موضوعية: | accuracy, intraoral scan, trueness, digital impression, gypsum check, passive fit, Technology, Engineering (General). Civil engineering (General), TA1-2040, Biology (General), QH301-705.5, Physics, QC1-999, Chemistry, QD1-999 |
الوصف: | Despite many advantages, digital impressions, when compared to the conventional one, produce contrasting results and their complete substitution is still under debate. This comparative study aims to test a way to perform a clinical evaluation of digital impression Accuracy and Trueness with a gypsum check. After calculating the Trueness, Precision, and Accuracy of the digital impressions, a gypsum check was fabricated and screwed on implant abutments. The impression was not considered reliable if the gypsum check fractured during the insertion. The gypsum check test was correlated to a cut-off of 100 µm Trueness. Mean Trueness was 151.19 ± 37.23 µm of the first optical impression and 125.47 ± 41.90 µm of the second optical impression. The Precision mean was 39.76 ± 10.89 µm. The mean Accuracy percentage was 98.69 ± 0.29%. The gypsum checks fractured 10 times on 42 tests, and in any case, the Trueness value was above the 100 µm cut off, with a p = 0.001. A gypsum check screwed onto an implant abutment could be considered a way to perform clinical measurement of Trueness, allowing the clinician to understand if the Trueness value is higher or lower than 100 µm and reflecting the reliability of digital impressions. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 2076-3417 |
Relation: | https://www.mdpi.com/2076-3417/13/13/7358; https://doaj.org/toc/2076-3417 |
DOI: | 10.3390/app13137358 |
URL الوصول: | https://doaj.org/article/679a4853b61941aa9a1fd9c162261d3e |
رقم الأكسشن: | edsdoj.679a4853b61941aa9a1fd9c162261d3e |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 20763417 |
---|---|
DOI: | 10.3390/app13137358 |