دورية أكاديمية

Validation of MIPAS IMK/IAA temperature, water vapor, and ozone profiles with MOHAVE-2009 campaign measurements

التفاصيل البيبلوغرافية
العنوان: Validation of MIPAS IMK/IAA temperature, water vapor, and ozone profiles with MOHAVE-2009 campaign measurements
المؤلفون: G. P. Stiller, M. Kiefer, E. Eckert, T. von Clarmann, S. Kellmann, M. García-Comas, B. Funke, T. Leblanc, E. Fetzer, L. Froidevaux, M. Gomez, E. Hall, D. Hurst, A. Jordan, N. Kämpfer, A. Lambert, I. S. McDermid, T. McGee, L. Miloshevich, G. Nedoluha, W. Read, M. Schneider, M. Schwartz, C. Straub, G. Toon, L. W. Twigg, K. Walker, D. N. Whiteman
المصدر: Atmospheric Measurement Techniques, Vol 5, Iss 2, Pp 289-320 (2012)
بيانات النشر: Copernicus Publications, 2012.
سنة النشر: 2012
المجموعة: LCC:Environmental engineering
LCC:Earthwork. Foundations
مصطلحات موضوعية: Environmental engineering, TA170-171, Earthwork. Foundations, TA715-787
الوصف: MIPAS observations of temperature, water vapor, and ozone in October 2009 as derived with the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK) and CSIC, Instituto de Astrofísica de Andalucía (IAA) and retrieved from version 4.67 level-1b data have been compared to co-located field campaign observations obtained during the MOHAVE-2009 campaign at the Table Mountain Facility near Pasadena, California in October 2009. The MIPAS measurements were validated regarding any potential biases of the profiles, and with respect to their precision estimates. The MOHAVE-2009 measurement campaign provided measurements of atmospheric profiles of temperature, water vapor/relative humidity, and ozone from the ground to the mesosphere by a suite of instruments including radiosondes, ozonesondes, frost point hygrometers, lidars, microwave radiometers and Fourier transform infra-red (FTIR) spectrometers. For MIPAS temperatures (version V4O_T_204), no significant bias was detected in the middle stratosphere; between 22 km and the tropopause MIPAS temperatures were found to be biased low by up to 2 K, while below the tropopause, they were found to be too high by the same amount. These findings confirm earlier comparisons of MIPAS temperatures to ECMWF data which revealed similar differences. Above 12 km up to 45 km, MIPAS water vapor (version V4O_H2O_203) is well within 10% of the data of all correlative instruments. The well-known dry bias of MIPAS water vapor above 50 km due to neglect of non-LTE effects in the current retrievals has been confirmed. Some instruments indicate that MIPAS water vapor might be biased high by 20 to 40% around 10 km (or 5 km below the tropopause), but a consistent picture from all comparisons could not be derived. MIPAS ozone (version V4O_O3_202) has a high bias of up to +0.9 ppmv around 37 km which is due to a non-identified continuum like radiance contribution. No further significant biases have been detected. Cross-comparison to co-located observations of other satellite instruments (Aura/MLS, ACE-FTS, AIRS) is provided as well.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1867-1381
1867-8548
Relation: http://www.atmos-meas-tech.net/5/289/2012/amt-5-289-2012.pdf; https://doaj.org/toc/1867-1381; https://doaj.org/toc/1867-8548
DOI: 10.5194/amt-5-289-2012
URL الوصول: https://doaj.org/article/67deabb0467f423eafb87c60f1f1bbcc
رقم الأكسشن: edsdoj.67deabb0467f423eafb87c60f1f1bbcc
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:18671381
18678548
DOI:10.5194/amt-5-289-2012