دورية أكاديمية
Investigation of MAF for Finishing the Inner Wall of Super-Slim Cardiovascular Stents Tube
العنوان: | Investigation of MAF for Finishing the Inner Wall of Super-Slim Cardiovascular Stents Tube |
---|---|
المؤلفون: | Guangxin Liu, Yugang Zhao, Zhihao Li, Chen Cao, Jianbing Meng, Hanlin Yu, Haiyun Zhang |
المصدر: | Materials, Vol 16, Iss 8, p 3022 (2023) |
بيانات النشر: | MDPI AG, 2023. |
سنة النشر: | 2023 |
المجموعة: | LCC:Technology LCC:Electrical engineering. Electronics. Nuclear engineering LCC:Engineering (General). Civil engineering (General) LCC:Microscopy LCC:Descriptive and experimental mechanics |
مصطلحات موضوعية: | CBN magnetic abrasive, MAF, cardiovascular stents, Ni-Ti alloy, response surface optimization, Technology, Electrical engineering. Electronics. Nuclear engineering, TK1-9971, Engineering (General). Civil engineering (General), TA1-2040, Microscopy, QH201-278.5, Descriptive and experimental mechanics, QC120-168.85 |
الوصف: | The internal wall of cardiovascular stent tubing produced by a drawing process has defects such as pits and bumps, making the surface rough and unusable. In this research, the challenge of finishing the inner wall of a super-slim cardiovascular stent tube was solved by magnetic abrasive finishing. Firstly, a spherical CBN magnetic abrasive was prepared by a new method, plasma molten metal powders bonding with hard abrasives; then, a magnetic abrasive finishing device was developed to remove the defect layer from the inner wall of ultrafine long cardiovascular stent tubing; finally, response surface tests were performed and parameters were optimized. The results show that the prepared spherical CBN magnetic abrasive has a perfect spherical appearance; the sharp cutting edges cover the surface layer of the iron matrix; the developed magnetic abrasive finishing device for a ultrafine long cardiovascular stent tube meets the processing requirements; the process parameters are optimized by the established regression model; and the inner wall roughness (Ra) of the nickel–titanium alloy cardiovascular stents tube is reduced from 0.356 μm to 0.083 μm, with an error of 4.3% from the predicted value. Magnetic abrasive finishing effectively removed the inner wall defect layer and reduced the roughness, and this solution provides a reference for polishing the inner wall of ultrafine long tubes. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 1996-1944 |
Relation: | https://www.mdpi.com/1996-1944/16/8/3022; https://doaj.org/toc/1996-1944 |
DOI: | 10.3390/ma16083022 |
URL الوصول: | https://doaj.org/article/6a1a2c7cf8be472d821f1e7706920cb8 |
رقم الأكسشن: | edsdoj.6a1a2c7cf8be472d821f1e7706920cb8 |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 19961944 |
---|---|
DOI: | 10.3390/ma16083022 |