دورية أكاديمية

Evaluation of the efficacy and safety of amustaline/glutathione pathogen-reduced RBCs in complex cardiac surgery: the Red Cell Pathogen Inactivation (ReCePI) study—protocol for a phase 3, randomized, controlled trial

التفاصيل البيبلوغرافية
العنوان: Evaluation of the efficacy and safety of amustaline/glutathione pathogen-reduced RBCs in complex cardiac surgery: the Red Cell Pathogen Inactivation (ReCePI) study—protocol for a phase 3, randomized, controlled trial
المؤلفون: Edward L. Snyder, Michael E. Sekela, Ian J. Welsby, Yoshiya Toyoda, Mohamed Alsammak, Neel R. Sodha, Thomas M. Beaver, J. Peter R. Pelletier, James D. Gorham, John S. McNeil, Roman M. Sniecinski, Ronald G. Pearl, Gregory A. Nuttall, Ravi Sarode, T. Brett Reece, Alesia Kaplan, Robertson D. Davenport, Tina S. Ipe, Peyman Benharash, Ileana Lopez-Plaza, Richard R. Gammon, Patrick Sadler, John P. Pitman, Kathy Liu, Stanley Bentow, Laurence Corash, Nina Mufti, Jeanne Varrone, Richard J. Benjamin, for the ReCePI study group
المصدر: Trials, Vol 24, Iss 1, Pp 1-13 (2023)
بيانات النشر: BMC, 2023.
سنة النشر: 2023
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: Amustaline/GSH, INTERCEPT, Pathogen reduction, Transfusion-transmitted infections, Randomized controlled trial, Cardiac surgery, Medicine (General), R5-920
الوصف: Abstract Background Red blood cell (RBC) transfusion is a critical supportive therapy in cardiovascular surgery (CVS). Donor selection and testing have reduced the risk of transfusion-transmitted infections; however, risks remain from bacteria, emerging viruses, pathogens for which testing is not performed and from residual donor leukocytes. Amustaline (S-303)/glutathione (GSH) treatment pathogen reduction technology is designed to inactivate a broad spectrum of infectious agents and leukocytes in RBC concentrates. The ReCePI study is a Phase 3 clinical trial designed to evaluate the efficacy and safety of pathogen-reduced RBCs transfused for acute anemia in CVS compared to conventional RBCs, and to assess the clinical significance of treatment-emergent RBC antibodies. Methods ReCePI is a prospective, multicenter, randomized, double-blinded, active-controlled, parallel-design, non-inferiority study. Eligible subjects will be randomized up to 7 days before surgery to receive either leukoreduced Test (pathogen reduced) or Control (conventional) RBCs from surgery up to day 7 post-surgery. The primary efficacy endpoint is the proportion of patients transfused with at least one study transfusion with an acute kidney injury (AKI) diagnosis defined as any increased serum creatinine (sCr) level ≥ 0.3 mg/dL (or 26.5 µmol/L) from pre-surgery baseline within 48 ± 4 h of the end of surgery. The primary safety endpoints are the proportion of patients with any treatment-emergent adverse events (TEAEs) related to study RBC transfusion through 28 days, and the proportion of patients with treatment-emergent antibodies with confirmed specificity to pathogen-reduced RBCs through 75 days after the last study transfusion. With ≥ 292 evaluable, transfused patients (> 146 per arm), the study has 80% power to demonstrate non-inferiority, defined as a Test group AKI incidence increase of no more than 50% of the Control group rate, assuming a Control incidence of 30%. Discussion RBCs are transfused to prevent tissue hypoxia caused by surgery-induced bleeding and anemia. AKI is a sensitive indicator of renal hypoxia and a novel endpoint for assessing RBC efficacy. The ReCePI study is intended to demonstrate the non-inferiority of pathogen-reduced RBCs to conventional RBCs in the support of renal tissue oxygenation due to acute anemia and to characterize the incidence of treatment-related antibodies to RBCs.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1745-6215
Relation: https://doaj.org/toc/1745-6215
DOI: 10.1186/s13063-023-07831-x
URL الوصول: https://doaj.org/article/6afcdc33fc664ea1b6806a81a0f891ba
رقم الأكسشن: edsdoj.6afcdc33fc664ea1b6806a81a0f891ba
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17456215
DOI:10.1186/s13063-023-07831-x