دورية أكاديمية

The Comparison of Lower Extremity Length and Angle between Computed Radiography-Based Teleoroentgenogram and EOS® Imaging System

التفاصيل البيبلوغرافية
العنوان: The Comparison of Lower Extremity Length and Angle between Computed Radiography-Based Teleoroentgenogram and EOS® Imaging System
المؤلفون: Kwang-Rak Park, Jae-Ho Lee, Dae-Soo Kim, Ho Ryu, Jaeho Kim, Chang-Jin Yon, Si-Wook Lee
المصدر: Diagnostics, Vol 12, Iss 5, p 1052 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: computed radiography-based teleoroentgenogram, EOS® imaging system, limb length, angular deformity, Medicine (General), R5-920
الوصف: Background and objectives: The differences between computed radiography-based teleoroentgenograms (CR-based teleoroentgenograms) and an EOS® imaging system were evaluated by measuring lower extremity lengths and alignments. Materials and methods: The leg length [L], femur length [F], tibia length [T], and hip–knee–ankle (HKA) angle were measured in 101 patients with lower extremity disease by a CR-based teleoroentgenogram with computed radiography and an EOS®. The additive length of the femoral and tibial segments (F + T) was determined by adding the two length values. Then, the differences among all five parameters between the two techniques were analyzed. The magnification (mm) was calculated by subtracting the length measurements on the EOS® from those in the scanogram. Furthermore, the magnification percentage (%) was calculated by dividing the magnification with the measurements on the EOS®. Results: The magnification errors (mean ± standard deviation), when comparing both right and left sides, were 7.80 ± 1.41%, 7.3 ± 6.01%, 5.16 ± 1.25%, and 6.45 ± 0.94% for L, F, T, and F + T, respectively. For limb length, the CR-based teleoroentgenogram had an average magnification of 6.8% (range, 5.2 to 7.8%) compared to the EOS® imaging. The two groups displayed a statistical difference (p < 0.01), except for the HKA angle. Conclusions: The CR-based teleoroentgenogram had a magnification of about 6.8% compared to the EOS® imaging system in evaluating lower extremity length. Therefore, more attention must be given to CR-based teleoroentgenograms to correct angular deformities.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2075-4418
Relation: https://www.mdpi.com/2075-4418/12/5/1052; https://doaj.org/toc/2075-4418
DOI: 10.3390/diagnostics12051052
URL الوصول: https://doaj.org/article/c6b4666ecb5c4f78a55d9035db23339c
رقم الأكسشن: edsdoj.6b4666ecb5c4f78a55d9035db23339c
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20754418
DOI:10.3390/diagnostics12051052