دورية أكاديمية

Classical and new bioerosion trace fossils in Cretaceous belemnite guards characterised via micro-CT

التفاصيل البيبلوغرافية
العنوان: Classical and new bioerosion trace fossils in Cretaceous belemnite guards characterised via micro-CT
المؤلفون: M. Wisshak, J. Titschack, W.-A. Kahl, P. Girod
المصدر: Fossil Record, Vol 20, Pp 173-199 (2017)
بيانات النشر: Pensoft Publishers, 2017.
سنة النشر: 2017
المجموعة: LCC:Paleontology
مصطلحات موضوعية: Paleontology, QE701-760
الوصف: The ongoing technical revolution in non-destructive 3-D visualisation via micro-computed tomography (micro-CT) finds a valuable application in the studies of bioerosion trace fossils, since their three-dimensional architecture is hidden within hard substrates. This technique, in concert with advanced segmentation algorithms, allows a detailed visualisation and targeted morphometric analyses even of those bioerosion traces that are otherwise inaccessible to the widely applied cast-embedding technique, because they either are filled with lithified sediment or cement or are preserved in inherently insoluble or silicified host substrates, or because they are established type material and should not be altered. In the present contribution selected examples of such cases are illustrated by reference to bioerosion trace fossils preserved in Late Cretaceous belemnite guards from the European Chalk Province. These case studies comprise an analysis of a diverse ichno-assemblage found associated with the lectotype of the microboring Dendrina dendrina (Morris, 1851) in a belemnite from the upper Campanian to lower Maastrichtian chalk of Norfolk, England, and the description of two new bioerosion trace fossils with type specimens found in belemnite guards from the lower Campanian limestones of Höver, Germany. The latter are Lapispecus hastatus isp. n., a tubular and occasionally branched macroboring for which a sipunculan or a phoronid trace maker are discussed, and Entobia colaria isp. n., a camerate network formed by an excavating sponge that eroded diagnostic grated apertures at the locations of the presumed inhalant papillae or exhaling pores, adding to or replacing filtering devices that are otherwise made of tissue and spicules. As an added value to the non-destructive visualisation procedure, the processed X-ray micro-CT scans of the studied type material provide 3-D models that may now serve as digitypes that can be studied as digital facsimile without the necessity of consulting the actual type specimens.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2193-0066
2193-0074
Relation: https://www.foss-rec.net/20/173/2017/fr-20-173-2017.pdf; https://doaj.org/toc/2193-0066; https://doaj.org/toc/2193-0074
DOI: 10.5194/fr-20-173-2017
URL الوصول: https://doaj.org/article/6bddeb21cf0d408c840e57206826b5b1
رقم الأكسشن: edsdoj.6bddeb21cf0d408c840e57206826b5b1
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21930066
21930074
DOI:10.5194/fr-20-173-2017