دورية أكاديمية

Analysis of Neat Biofluids Obtained During Cardiac Surgery Using Nanoparticle Tracking Analysis: Methodological Considerations

التفاصيل البيبلوغرافية
العنوان: Analysis of Neat Biofluids Obtained During Cardiac Surgery Using Nanoparticle Tracking Analysis: Methodological Considerations
المؤلفون: Andrew I. U. Shearn, Sezin Aday, Soumaya Ben-Aicha, Pauline Carnell-Morris, Agnieszka Siupa, Gianni D. Angelini, Aled Clayton, Chantal Boulanger, Prakash Punjabi, Costanza Emanueli, Giovanni Biglino
المصدر: Frontiers in Cell and Developmental Biology, Vol 8 (2020)
بيانات النشر: Frontiers Media S.A., 2020.
سنة النشر: 2020
المجموعة: LCC:Biology (General)
مصطلحات موضوعية: cardiac surgery, exosome (vesicle), exosomal biomarkers, nanopartcicles, NTA (nanoparticle tracking analysis), Biology (General), QH301-705.5
الوصف: Small extracellular vesicles (sEVs) are those nanovesicles 30–150 nm in size with a role in cell signalling and potential as biomarkers of disease. Nanoparticle tracking analysis (NTA) techniques are commonly used to measure sEV concentration in biofluids. However, this quantification technique can be susceptible to sample handing and machine settings. Moreover, some classes of lipoproteins are of similar sizes and could therefore confound sEV quantification, particularly in blood-derived preparations, such serum and plasma. Here we have provided methodological information on NTA measurements and systematically investigated potential factors that could interfere with the reliability and repeatability of results obtained when looking at neat biofluids (i.e., human serum and pericardial fluid) obtained from patients undergoing cardiac surgery and from healthy controls. Data suggest that variables that can affect vesicle quantification include the level of contamination from lipoproteins, number of sample freeze/thaw cycles, sample filtration, using saline-based diluents, video length and keeping the number of particles per frame within defined limits. Those parameters that are of less concern include focus, the “Maximum Jump” setting and the number of videos recorded. However, if these settings are clearly inappropriate the results obtained will be spurious. Similarly, good experimental practice suggests that multiple videos should be recorded. In conclusion, NTA is a perfectible, but still commonly used system for sEVs analyses. Provided users handle their samples with a highly robust and consistent protocol, and accurately report these aspects, they can obtain data that could potentially translate into new clinical biomarkers for diagnosis and monitoring of cardiovascular disease.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2296-634X
Relation: https://www.frontiersin.org/article/10.3389/fcell.2020.00367/full; https://doaj.org/toc/2296-634X
DOI: 10.3389/fcell.2020.00367
URL الوصول: https://doaj.org/article/6cd858cf2f7d4074b1a303dc745e9b71
رقم الأكسشن: edsdoj.6cd858cf2f7d4074b1a303dc745e9b71
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2296634X
DOI:10.3389/fcell.2020.00367