Analysis of the Ventilation Performance of a Solar Chimney Coupled to an Outdoor Wind and Indoor Heat Source

التفاصيل البيبلوغرافية
العنوان: Analysis of the Ventilation Performance of a Solar Chimney Coupled to an Outdoor Wind and Indoor Heat Source
المؤلفون: Shuaikun Yue, Zhong Ge, Jian Xu, Jianbin Xie, Zhiyong Xie, Songyuan Zhang, Jian Li
المصدر: Applied Sciences, Vol 13, Iss 4, p 2585 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Technology
LCC:Engineering (General). Civil engineering (General)
LCC:Biology (General)
LCC:Physics
LCC:Chemistry
مصطلحات موضوعية: solar chimney, indoor heat source, natural ventilation, ventilation volume, solar radiation, Technology, Engineering (General). Civil engineering (General), TA1-2040, Biology (General), QH301-705.5, Physics, QC1-999, Chemistry, QD1-999
الوصف: The effects of different solar radiation intensities, heat flow density of indoor heat sources, outdoor wind speed, and the relative location of indoor heat sources on the natural ventilation performance of solar chimneys are investigated through three-dimensional numerical simulations. The mechanism of the mutual coupling of the solar chimney effect with the outdoor wind and indoor heat source heat plume is explored. The results of the study show that when the structural parameters of the solar chimney are the same, the heat flow density on the surface of the indoor heat source, the outdoor wind speed and the solar radiation intensity all have a gaining effect on the ventilation performance of the solar chimney and the effects of the three on the ventilation of the solar chimney promote each other, when the solar radiation intensity is 200 W/m2, the outdoor wind speed is 1.0 m/s, and the indoor heat source heat flow density increases from 0 to 1 500 W/m2, the solar chimney ventilation volume increases from 0.393 m3/s to 0.519 m3/s, the maximum value of the increase is 32.1%. In the other two cases, the maximum increase in solar chimney ventilation is 176.7% and 33.1%, respectively. Under the same conditions, solar chimney ventilation is optimal when the heat source is in the middle of the room. The presence of outdoor wind, however, affects the optimum design parameters of the solar chimney. Compared to the case where no outdoor wind is taken into account, the optimum inlet width of 0.2–0.3 m for the solar chimney no longer applies with outdoor wind, with the optimum value rising to 0.5 m.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2076-3417
Relation: https://www.mdpi.com/2076-3417/13/4/2585; https://doaj.org/toc/2076-3417
DOI: 10.3390/app13042585
URL الوصول: https://doaj.org/article/6d991a94202d428db0937c35608a91d0
رقم الأكسشن: edsdoj.6d991a94202d428db0937c35608a91d0
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20763417
DOI:10.3390/app13042585