The Impact of Single Versus Dual Data Entry on Accuracy of Relational Database Information
العنوان: | The Impact of Single Versus Dual Data Entry on Accuracy of Relational Database Information |
---|---|
المؤلفون: | Willem Meeuwisse, Brent Hagel, Gordon Fick |
المصدر: | Journal of Innovation in Health Informatics, Vol 8, Iss 1, Pp 2-8 (1999) |
بيانات النشر: | BCS, The Chartered Institute for IT, 1999. |
سنة النشر: | 1999 |
المجموعة: | LCC:Computer applications to medicine. Medical informatics |
مصطلحات موضوعية: | Dual Data Entry, Relational Database, Cross-over trial., Computer applications to medicine. Medical informatics, R858-859.7 |
الوصف: | Objective: To evaluate the differences in entry errors associated with entry of prospective cohort data using a single versus a dual data entry system. Design: Cross-over trial Measurements: The database for the Canadian Intercollegiate Sport Injury Registry (CISIR) has, to date, used a dual data entry system. To test the differences in entry error, one season of injury and exposure (participation) data were entered for one sport from two participating institutions. A total of 5 data entry clerks were involved. Discrepancies between the final entries from both systems were flagged and checked against the original paper record. The number of instances where the dual entry system was correct but the single entry system was incorrect, and vice versa, were determined. Results: A total of 17,988 database fields were evaluated (15,509 text and 2,479 fixed response fields). There was a statistically significant difference in error where the dual entry system was correct but the single entry system was incorrect for 2 out of the 4 data entry modules. The percent accuracy using the single entry system was lower (99.35%) than that using the dual entry system (99.83%). Conclusions: Although the single entry system was statistically different from the dual entry system, the percent accuracy remained high and the errors did not cluster in one specific field. Given the doubling of entry costs with a dual entry system, it is recommended that a single entry system be used for the CISIR. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 2058-4555 2058-4563 |
Relation: | https://hijournal.bcs.org/index.php/jhi/article/view/220; https://doaj.org/toc/2058-4555; https://doaj.org/toc/2058-4563 |
DOI: | 10.14236/jhi.v8i1.220 |
URL الوصول: | https://doaj.org/article/6e4ba1f5d40042cb8ccd3bf6e47a96d7 |
رقم الأكسشن: | edsdoj.6e4ba1f5d40042cb8ccd3bf6e47a96d7 |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 20584555 20584563 |
---|---|
DOI: | 10.14236/jhi.v8i1.220 |