دورية أكاديمية

A Comparison Study Between CNN-Based Deformed Planning CT and CycleGAN-Based Synthetic CT Methods for Improving iCBCT Image Quality

التفاصيل البيبلوغرافية
العنوان: A Comparison Study Between CNN-Based Deformed Planning CT and CycleGAN-Based Synthetic CT Methods for Improving iCBCT Image Quality
المؤلفون: Bo Yang, Yankui Chang, Yongguang Liang, Zhiqun Wang, Xi Pei, Xie George Xu, Jie Qiu
المصدر: Frontiers in Oncology, Vol 12 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: iCBCT, registration, sCT generation, pelvic, CycleGAN, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: PurposeThe aim of this study is to compare two methods for improving the image quality of the Varian Halcyon cone-beam CT (iCBCT) system through the deformed planning CT (dpCT) based on the convolutional neural network (CNN) and the synthetic CT (sCT) generation based on the cycle-consistent generative adversarial network (CycleGAN).MethodsA total of 190 paired pelvic CT and iCBCT image datasets were included in the study, out of which 150 were used for model training and the remaining 40 were used for model testing. For the registration network, we proposed a 3D multi-stage registration network (MSnet) to deform planning CT images to agree with iCBCT images, and the contours from CT images were propagated to the corresponding iCBCT images through a deformation matrix. The overlap between the deformed contours (dpCT) and the fixed contours (iCBCT) was calculated for purposes of evaluating the registration accuracy. For the sCT generation, we trained the 2D CycleGAN using the deformation-registered CT-iCBCT slicers and generated the sCT with corresponding iCBCT image data. Then, on sCT images, physicians re-delineated the contours that were compared with contours of manually delineated iCBCT images. The organs for contour comparison included the bladder, spinal cord, femoral head left, femoral head right, and bone marrow. The dice similarity coefficient (DSC) was used to evaluate the accuracy of registration and the accuracy of sCT generation.ResultsThe DSC values of the registration and sCT generation were found to be 0.769 and 0.884 for the bladder (p < 0.05), 0.765 and 0.850 for the spinal cord (p < 0.05), 0.918 and 0.923 for the femoral head left (p > 0.05), 0.916 and 0.921 for the femoral head right (p > 0.05), and 0.878 and 0.916 for the bone marrow (p < 0.05), respectively. When the bladder volume difference in planning CT and iCBCT scans was more than double, the accuracy of sCT generation was significantly better than that of registration (DSC of bladder: 0.859 vs. 0.596, p < 0.05).ConclusionThe registration and sCT generation could both improve the iCBCT image quality effectively, and the sCT generation could achieve higher accuracy when the difference in planning CT and iCBCT was large.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2234-943X
Relation: https://www.frontiersin.org/articles/10.3389/fonc.2022.896795/full; https://doaj.org/toc/2234-943X
DOI: 10.3389/fonc.2022.896795
URL الوصول: https://doaj.org/article/6eb26e605aec4cfdbc3795d61d194b32
رقم الأكسشن: edsdoj.6eb26e605aec4cfdbc3795d61d194b32
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2234943X
DOI:10.3389/fonc.2022.896795