دورية أكاديمية

A força de atrito em braquetes plásticos e de aço inoxidável com a utilização de quatro diferentes tipos de amarração Frictional forces in stainless steel and plastic brackets using four types of wire ligation

التفاصيل البيبلوغرافية
العنوان: A força de atrito em braquetes plásticos e de aço inoxidável com a utilização de quatro diferentes tipos de amarração Frictional forces in stainless steel and plastic brackets using four types of wire ligation
المؤلفون: Vanessa Nínia Correia Lima, Maria Elisa Rodrigues Coimbra, Carla D'Agostini Derech, Antônio Carlos de Oliveira Ruellas
المصدر: Dental Press Journal of Orthodontics, Vol 15, Iss 2, Pp 82-86 (2010)
بيانات النشر: Dental Press Editora, 2010.
سنة النشر: 2010
المجموعة: LCC:Dentistry
مصطلحات موضوعية: Atrito, Amarração ortodôntica, Braquete metálico, Braquete plástico, Friction, Orthodontic ligation, Metal bracket, Plastic bracket, Dentistry, RK1-715
الوصف: OBJETIVO: a finalidade deste estudo in vitro foi avaliar e comparar a resistência friccional em braquetes de aço inoxidável e de policarbonato compósito amarrados com fio metálico e elastômeros. MÉTODOS: foram utilizados quatro braquetes de aço inoxidável e quatro de policarbonato compósito (PC) para pré-molares levados à máquina universal de ensaio mecânico para a tração de um segmento de fio de aço inoxidável 0,019" x 0,025" na velocidade de 0,5mm/min, com 8mm de deslocamento total. A forma de amarração variou entre as seguintes possibilidades: amarração metálica com pinça de Steiner, metálica com pinça Mathieu, elastômero da marca Morelli e elastômero da marca TP Orthodontics. RESULTADOS E CONCLUSÕES: os módulos elastoméricos geraram mais atrito do que os metálicos e a amarração com pinça Mathieu provocou menor atrito quando comparada a todas as situações avaliadas. Os braquetes de PC geraram menor atrito do que os metálicos, porém, na escolha do material a ser utilizado na clínica, outras variáveis - tais como a resistência ao cisalhamento e à fratura, a estabilidade de cor e a aderência por microrganismos - devem ser consideradas.OBJECTIVE: This in vitro study evaluated and compared the frictional resistance of stainless steel and polycarbonate (PC) composite brackets tied with metal wire and elastomeric ligation. METHODS: Four stainless steel and four polycarbonate composite brackets for premolars were placed in a universal testing machine for the traction of a piece of 0.019 x 0.025-in wire at 0.5 mm/min and total displacement of 8 mm. Ligations were performed according to the following alternatives: metal ligation with Steiner tying pliers; metal ligation using Mathieu tying pliers; Morelli™ elastomeric ligation; and TP Orthodontics™ elastomeric ligation. RESULTS AND CONCLUSIONS: Elastomeric modules generated more friction than the metal ligations, and the ligation with the Mathieu tying pliers caused less friction than all the other conditions under study. PC brackets generated less friction than metal brackets, but the choice of material to be used in clinical conditions should take into consideration other variables, such as resistance to shearing and to fractures, as well as color stability and microorganism adherence.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Portuguese
تدمد: 2176-9451
2177-6709
Relation: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512010000200011; https://doaj.org/toc/2176-9451; https://doaj.org/toc/2177-6709
DOI: 10.1590/S2176-94512010000200011
URL الوصول: https://doaj.org/article/6f56344f13454c1eb1e74d5fac1c38d5
رقم الأكسشن: edsdoj.6f56344f13454c1eb1e74d5fac1c38d5
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21769451
21776709
DOI:10.1590/S2176-94512010000200011