Dual-Energy Computed Tomography-Based Iodine Concentration Estimation for Evaluating Choroidal Malignant Melanoma Response to Treatment: Optimization and Primary Validation

التفاصيل البيبلوغرافية
العنوان: Dual-Energy Computed Tomography-Based Iodine Concentration Estimation for Evaluating Choroidal Malignant Melanoma Response to Treatment: Optimization and Primary Validation
المؤلفون: Hiroki Tsuchiya, Yasuhiko Tachibana, Riwa Kishimoto, Tokuhiko Omatsu, Eika Hotta, Katsuyuki Tanimoto, Masaru Wakatsuki, Takayuki Obata, Hiroshi Tsuji
المصدر: Diagnostics, Vol 12, Iss 11, p 2692 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: choroidal malignant melanoma, contrast-enhanced CT, dual-energy CT, charged-particle radiation therapy, phantom study, clinical study, Medicine (General), R5-920
الوصف: Contrast-enhanced imaging for choroidal malignant melanoma (CMM) is mostly limited to detecting metastatic tumors, possibly due to difficulties in fixing the eye position. We aimed to (1) validate the appropriateness of estimating iodine concentration based on dual-energy computed tomography (DECT) for CMM and optimize the calculation parameters for estimation, and (2) perform a primary clinical validation by assessing the ability of this technique to show changes in CMM after charged-particle radiation therapy. The accuracy of the optimized estimate (eIC_optimized) was compared to an estimate obtained by commercial software (eIC_commercial) by determining the difference from the ground truth. Then, eIC_optimized, tumor volume, and CT values (80 kVp, 140 kVp, and synthesized 120 kVp) were measured at pre-treatment and 3 months and 1.5–2 years after treatment. The difference from the ground truth was significantly smaller in eIC_optimized than in eIC_commercial (p < 0.01). Tumor volume, CT values, and eIC_optimized all decreased significantly at 1.5–2 years after treatment, but only eIC_commercial showed a significant reduction at 3 months after treatment (p < 0.01). eIC_optimized can quantify contrast enhancement in primary CMM lesions and has high sensitivity for detecting the response to charged-particle radiation therapy, making it potentially useful for treatment monitoring.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2075-4418
Relation: https://www.mdpi.com/2075-4418/12/11/2692; https://doaj.org/toc/2075-4418
DOI: 10.3390/diagnostics12112692
URL الوصول: https://doaj.org/article/6f7dcfe585ce419a8453fe3e02a6318d
رقم الأكسشن: edsdoj.6f7dcfe585ce419a8453fe3e02a6318d
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20754418
DOI:10.3390/diagnostics12112692