دورية أكاديمية

Transcranial Doppler Echography Measurement in Hemodialysis Patients: The Potential Role of Angiotensin II Receptor Blockades on Cerebrovascular Circulation

التفاصيل البيبلوغرافية
العنوان: Transcranial Doppler Echography Measurement in Hemodialysis Patients: The Potential Role of Angiotensin II Receptor Blockades on Cerebrovascular Circulation
المؤلفون: Kyoko Maesato, Shuzo Kobayashi, Takayasu Ohtake, Yasuhiro Mochida, Kunihiro Ishioka, Machiko Oka, Hidekazu Moriya, Sumi Hidaka
المصدر: Journal of Clinical Medicine, Vol 12, Iss 6, p 2295 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Medicine
مصطلحات موضوعية: angiotensin II receptor blockade, hemodialysis, intracranial doppler echography, cerebral artery velocity, Medicine
الوصف: Background: Although hemodialysis (HD) patients have an elevated risk of strokes, there are few reports about transcranial doppler (TCD) echography measurements. It is well-known that angiotensin II receptor blockades (ARBs) protect against cardiovascular complications. In this study, we measured intracranial artery (ICA) velocity using TCD echography and studied the associated factors with its velocity in HD patients by a comparison with or without ARBs. Methods: We conducted a cross-sectional study in a single hospital. We included 61 patients who had measurable ICA velocity by TCD echography. Among them, the ARB usage group consisted of 22 subjects, whilst the non-ARB usage group consisted of 39 subjects. Results: Patients in the ARB (+) and ARB (-) groups did not show any difference in basic characteristics. ICA blood flow velocity in all intracranial arteries tended to show greater values in the ARB group than those in the non-ARB group. Particularly, blood velocity in the middle cerebral artery (MCA) (maximal flow velocity) statistically increased in the ARB group, respectively. In a univariate analysis, MCA maximum velocity was significantly associated with ARB usage (p = 0.011) and low hematocrit levels (p = 0.045). The multivariate analysis chose only ARB usage as an independent factor associated with left MCA maximum velocity (p = 0.022). Conclusions: We showed that dialysis patients with ARBs have significantly higher ICA blood velocity. ARBs might have a potential benefit for maintaining ICA blood flow in HD patients.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2077-0383
Relation: https://www.mdpi.com/2077-0383/12/6/2295; https://doaj.org/toc/2077-0383
DOI: 10.3390/jcm12062295
URL الوصول: https://doaj.org/article/728c3bde8ef845ba88451b4420e2ee9f
رقم الأكسشن: edsdoj.728c3bde8ef845ba88451b4420e2ee9f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20770383
DOI:10.3390/jcm12062295