دورية أكاديمية

Determination of 25OHD in Serum Based on Quadrupole-Linear Ion Trap Tandem Mass Spectrometric Technique

التفاصيل البيبلوغرافية
العنوان: Determination of 25OHD in Serum Based on Quadrupole-Linear Ion Trap Tandem Mass Spectrometric Technique
المؤلفون: XIE Jie, YI Ke-ke, GAO Wen-jing, LIU Hao, LI Jia-lian, HUANG Ze-jian, LIU Mei-ying, YU Qing-ni, WANG Han-wen, JIANG You, DAI Xin-hua, FANG Xiang
المصدر: Zhipu Xuebao, Vol 44, Iss 1, Pp 13-24 (2023)
بيانات النشر: Editorial Board of Journal of Chinese Mass Spectrometry Society, 2023.
سنة النشر: 2023
المجموعة: LCC:Chemistry
مصطلحات موضوعية: liquid chromatography tandem mass spectrometry (lc-ms/ms), isotope dilution mass spectrometry, quadrupole, linear ion trap, 25ohd, Chemistry, QD1-999
الوصف: Vitamin D deficiency and insufficiency is a global health issue that afflicts people of different age groups all over the world. As a reliable indicator for the evaluation of vitamin D, 25OHD is usually determined by LC-MS/MS. The tandem mass spectrometry based on ion trap has the characteristics of simple structure and high sensitivity. However, there are some problems such as narrow linear range and space charge effect, which limit its analysis of trace substances in complex matrix samples. In this study, the device and technology of a new quadrupole linear ion trap mass spectrometry was used to reduce the space charge interference of trace or ultra trace target ions by high abundance impurity ions in complex matrices. For the first time, isotope dilution mass spectrometry for accurate measurement of serum 25OHD was established by QLIT-6610MD, which is quadrupole-linear ion trap tandem mass spectrometer, and was independently developed by Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology. Serum samples were precipitated with methanol, extracted with n-hexane, dried with liquid nitrogen, redissolved in the initial mobile phase, and determined by QLIT-6610MD. The matrix-matched standard curve was used for quantification. The linear ranges of 25OHD2 and 25OHD3 were in the range of 0.78-50 μg/L and 1.56-100 μg/L with R2>0.999 9, respectively. The detection and quantification limits of 25OHD2 and 25OHD3 were 0.06, 0.12 μg/L and 0.02, 0.06 μg/L, respectively. The precision of quality control was better than 4.06%. The recoveries ranged from 99.25% to 108.38%, and the coefficients of variation were all less than 5.1%. After the method confirmation, the quantitative results of clinical samples were compared with triple quadrupole tandem mass spectrometry. 50 Clinical serum samples were measured and compared by QLIT-6610MD, AB 4500MD and YS EXACT 9900MD. The correlation and consistency of the data were analyzed by Pearson and Bland-Altman. The correlation coefficient of the three groups data was R≥0.998 0, P
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Chinese
تدمد: 1004-2997
Relation: http://www.jcmss.com.cn/CN/article/openArticlePDF.jsp?attachType=PDF&id=3118; https://doaj.org/toc/1004-2997
DOI: 10.7538/zpxb.2022.0103
URL الوصول: https://doaj.org/article/73c468f59a2f47bf91e4940019d6b9e5
رقم الأكسشن: edsdoj.73c468f59a2f47bf91e4940019d6b9e5
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:10042997
DOI:10.7538/zpxb.2022.0103