دورية أكاديمية

Comparative Evaluation of the Repair Bond Strength of Dental Resin Composite after Sodium Bicarbonate or Aluminum Oxide Air-Abrasion

التفاصيل البيبلوغرافية
العنوان: Comparative Evaluation of the Repair Bond Strength of Dental Resin Composite after Sodium Bicarbonate or Aluminum Oxide Air-Abrasion
المؤلفون: Kinga Dorottya Németh, Roland Told, Péter Szabó, Péter Maróti, Réka Szénai, Zsolt Balázs Pintér, Bálint Viktor Lovász, József Szalma, Edina Lempel
المصدر: International Journal of Molecular Sciences, Vol 24, Iss 14, p 11568 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Biology (General)
LCC:Chemistry
مصطلحات موضوعية: resin composite, repair bond strength, aluminum oxide, sodium bicarbonate, dental adhesive, Biology (General), QH301-705.5, Chemistry, QD1-999
الوصف: The dental prophylactic cleaning of a damaged resin-based composite (RBC) restoration with sodium bicarbonate can change the surface characteristics and influence the repair bond strength. The purpose of this study was to compare the effect of sodium bicarbonate (SB) and aluminum oxide (AO) surface treatments on the microtensile bond strength (µTBS) of repaired, aged RBC. Bar specimens were prepared from microhybrid RBC and aged in deionized water for 8 weeks. Different surface treatments (AO air-abrasion; SB air-polishing), as well as cleaning (phosphoric acid, PA; ethylene-diamine-tetraacetic-acid, EDTA) and adhesive applications (single bottle etch-and-rinse, ER; universal adhesive, UA), were used prior to the application of the repair RBC. Not aged and aged but not surface treated RBCs were used as positive and negative controls, respectively. The repaired blocks were cut into sticks using a precision grinding machine. The specimens were tested for tensile fracture and the µTBS values were calculated. Surface characteristics were assessed using scanning electron microscopy. AO-PA-UA (62.6 MPa) showed a 20% increase in µTBS compared to the NC (50.2 MPa), which proved to be the most significant. This was followed by SB-EDTA-UA (58.9 MPa) with an increase of 15%. In addition to AO-PA-UA, SB-EDTA-UA could also be a viable alternative in the RBC repair protocol.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1422-0067
1661-6596
Relation: https://www.mdpi.com/1422-0067/24/14/11568; https://doaj.org/toc/1661-6596; https://doaj.org/toc/1422-0067
DOI: 10.3390/ijms241411568
URL الوصول: https://doaj.org/article/774c4bf7d57c41c98f071d6248d095de
رقم الأكسشن: edsdoj.774c4bf7d57c41c98f071d6248d095de
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14220067
16616596
DOI:10.3390/ijms241411568