دورية أكاديمية

Water exchange colonoscopy decreased adenoma miss rates compared with literature data and local data with CO2 insufflation: an observational study

التفاصيل البيبلوغرافية
العنوان: Water exchange colonoscopy decreased adenoma miss rates compared with literature data and local data with CO2 insufflation: an observational study
المؤلفون: Chi-Liang Cheng, Yen-Lin Kuo, Yu-Hsi Hsieh, Jui-Hsiang Tang, Felix W. Leung
المصدر: BMC Gastroenterology, Vol 19, Iss 1, Pp 1-9 (2019)
بيانات النشر: BMC, 2019.
سنة النشر: 2019
المجموعة: LCC:Diseases of the digestive system. Gastroenterology
مصطلحات موضوعية: Colonoscopy, Water exchange, Carbon dioxide, Adenoma miss rate, Colon polyp, Diseases of the digestive system. Gastroenterology, RC799-869
الوصف: Abstract Background Reports showed adenoma miss rates (AMRs) of 22.5–27% in the right colon and 23.4–33.3% in the proximal colon. Missed lesions could contribute to postcolonoscopy cancers. Water exchange (WE) with near-complete removal of infused water during insertion increased adenoma detection rate but the impact on AMR had not been reported. We hypothesized that WE could reduce AMRs. Study 1 compared the AMRs of WE with literature data. Study 2 developed local AMR data with CO2 insufflation. Methods The lead author attended a research seminar in 2017 on WE colonoscopy. For performance improvement, study 1 was undertaken. When data in study 1 confirmed WE produced a considerably lower AMRs in the right and proximal colon, study 2 with CO2 insufflation was performed. Results Eighty-six patients completed each study. In study 1, WE removed 89% of infused water upon arrival to the cecum. The AMRs of right colon (17.5%) and proximal colon (15.5%) were considerably lower than those in the literature. Upon completion of study 2, compared with local data of CO2 insufflation, WE showed a significantly lower AMR in the right (17.5% vs. 33.8%, P = 0.034) and proximal (15.5% vs. 30.4%, P = 0.018) colon, respectively. The major limitation was that the investigation consisted of two consecutive observational studies, not a randomized controlled trial (RCT). Conclusions WE with near-complete (89%) removal of infused water during insertion significantly decreased AMRs in the right and proximal colon compared with literature data and those of CO2 insufflation in our hands. The provocative data warrant confirmation in a RCT. Trial registration NCT03832322 (Retrospectively registered on February 2, 2019).
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1471-230X
Relation: http://link.springer.com/article/10.1186/s12876-019-1065-2; https://doaj.org/toc/1471-230X
DOI: 10.1186/s12876-019-1065-2
URL الوصول: https://doaj.org/article/786020d5d13f456b9112098193fb814a
رقم الأكسشن: edsdoj.786020d5d13f456b9112098193fb814a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1471230X
DOI:10.1186/s12876-019-1065-2