دورية أكاديمية

Risk Factors for Cervical Disc Arthroplasty Subsidence with Bryan Disc—A Retrospective Observational Analysis

التفاصيل البيبلوغرافية
العنوان: Risk Factors for Cervical Disc Arthroplasty Subsidence with Bryan Disc—A Retrospective Observational Analysis
المؤلفون: Cheng-Ying Lee, Kuan-Kai Tung, Hsi-Kai Tsou, Wen-Hsien Chen, Chung-Yuh Tzeng, Ruei-Hong Lin, Tse-Yu Chen, Chih-Wei Huang, Ting-Hsien Kao
المصدر: Journal of Clinical Medicine, Vol 13, Iss 6, p 1589 (2024)
بيانات النشر: MDPI AG, 2024.
سنة النشر: 2024
المجموعة: LCC:Medicine
مصطلحات موضوعية: cervical disc arthroplasty, implant subsidence, functional spinal unit height, Bryan disc, mean disc height, oversized, Medicine
الوصف: Background: Cervical disc arthroplasty (CDA) is currently used instead of fusion to preserve cervical spine motion. Cervical implant subsidence is a potential complication after CDA. Methods: Radiological measurements were recorded via patient anteroposterior and lateral radiographs in the neutral position. Subsidence was defined as a decrease of 3 mm or more in functional spinal unit height (FSUH) from which was measured on a post-operative (OP) radiograph. Results: This study included 104 patients who underwent 153 CDA levels with the Bryan Disc. Approximately one-quarter of the implants (22.9%) showed subsidence. Binary logistic regression analysis indicated that pre-OP mean disc height (DH) was identified as an independent risk factor for subsidence in multivariate analysis (0.151, 95% Confidence Interval 0–0.073, p = 0.018). Receiver operating characteristic curve analysis (area under the curve = 0.852, sensitivity 84.7%, specificity 77.1%) revealed a cut-off value of 4.48 mm for pre-OP Mean-DH in the risk for implant subsidence. Conclusions: In this study, the subsidence rate significantly increased when the implants were oversized beyond a pre-OP Mean-DH of approximately >4 mm. Moreover, the implant subsidence incidence was higher than that reported in previous studies. This is possibly due to endplate over-preparation or disc space over-distraction during placement at the same height as the Bryan Disc (8.5 mm).
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2077-0383
Relation: https://www.mdpi.com/2077-0383/13/6/1589; https://doaj.org/toc/2077-0383
DOI: 10.3390/jcm13061589
URL الوصول: https://doaj.org/article/a792b3d5ccef4f70a9709fc4c91ffcb6
رقم الأكسشن: edsdoj.792b3d5ccef4f70a9709fc4c91ffcb6
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20770383
DOI:10.3390/jcm13061589