Evaluation of energy savings potential of variable refrigerant flow (VRF) from variable air volume (VAV) in the U.S. climate locations

التفاصيل البيبلوغرافية
العنوان: Evaluation of energy savings potential of variable refrigerant flow (VRF) from variable air volume (VAV) in the U.S. climate locations
المؤلفون: Dongsu Kim, Sam J. Cox, Heejin Cho, Piljae Im
المصدر: Energy Reports, Vol 3, Iss C, Pp 85-93 (2017)
بيانات النشر: Elsevier, 2017.
سنة النشر: 2017
المجموعة: LCC:Electrical engineering. Electronics. Nuclear engineering
مصطلحات موضوعية: Variable refrigerant flow, Rooftop unit, Variable air volume, Building simulation, U.S. climate zones, Electrical engineering. Electronics. Nuclear engineering, TK1-9971
الوصف: Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assess the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2352-4847
Relation: http://www.sciencedirect.com/science/article/pii/S2352484717300562; https://doaj.org/toc/2352-4847
DOI: 10.1016/j.egyr.2017.05.002
URL الوصول: https://doaj.org/article/7c5f456a46ae4e27bdd89baee4386b9e
رقم الأكسشن: edsdoj.7c5f456a46ae4e27bdd89baee4386b9e
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:23524847
DOI:10.1016/j.egyr.2017.05.002