دورية أكاديمية

Balloon expandable vs. self-expandable transcatheter aortic valve prosthesis short-term results of retrospective study

التفاصيل البيبلوغرافية
العنوان: Balloon expandable vs. self-expandable transcatheter aortic valve prosthesis short-term results of retrospective study
المؤلفون: Hr. Angelov, P. Simeonov, P. Krastev, F. Abedinov, J. Jorgova, D. Trendafilova
المصدر: Българска кардиология, Vol 28, Iss 2, Pp 90-95 (2022)
بيانات النشر: Pensoft Publishers, 2022.
سنة النشر: 2022
المجموعة: LCC:Medicine
LCC:Diseases of the circulatory (Cardiovascular) system
مصطلحات موضوعية: aortic stenosis, TAVI, balloon expandable, self-ex, Medicine, Diseases of the circulatory (Cardiovascular) system, RC666-701
الوصف: Transcutaneous aortic valve implantation has been established as an effective method for the treatment of highgrade aortic stenosis in non-operative, high-risk for conventional surgery patients. According to the developed implantation technologies, the prostheses are divided into balloon-expandable valve prostheses (balloon-expandable valves, BEV) and self-expanding valve prostheses (self-expanding prostheses SEV). The two types of devices have different models for implantation, stratum architecture, cusps characteristics, leading to different hemodynamics, frequency of use and performance of normal prosthesis function. The research aims to monitor the short-term results, up to 1 month after discharge, in terms of mortality, the manifestation of heart failure, (para) prosthetic regurgitation, implantation of a pacemaker, and vascular complications. Materials and methods: the article presents a retrospective follow-up of a total of 230 high-risk for conventional cardiac surgery patients with high-grade aortic stenosis treated in a cardiology clinic at UMHAT St. Ekaterina Sofia until 2020, divided into two groups depending on the implanted type of prosthesis. Conclusions: The results obtained based on our experience prove the safety of new prostheses. When choosing between BEV and SEV, the best clinical outcome requires a good knowledge of the strengths and weaknesses of using medical devices with a personalized approach consistent with the clinical and anatomical characteristics of the patient.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: Bulgarian
English
تدمد: 2683-1015
Relation: https://journal.bgcardio.org/article/83164/download/pdf/; https://journal.bgcardio.org/article/83164/download/xml/; https://journal.bgcardio.org/article/83164/; https://doaj.org/toc/2683-1015
DOI: 10.3897/bgcardio.28.e83164
URL الوصول: https://doaj.org/article/7db6b93872064deeb374be80a93f2d59
رقم الأكسشن: edsdoj.7db6b93872064deeb374be80a93f2d59
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:26831015
DOI:10.3897/bgcardio.28.e83164