دورية أكاديمية

NLFEA of Sulfate-Damaged Circular CFT Steel Columns Confined with CFRP Composites and Subjected to Axial and Cyclic Lateral Loads

التفاصيل البيبلوغرافية
العنوان: NLFEA of Sulfate-Damaged Circular CFT Steel Columns Confined with CFRP Composites and Subjected to Axial and Cyclic Lateral Loads
المؤلفون: Rajai Al-Rousan, Osama Nusier, Khairedin Abdalla, Mohammad Alhassan, Nikos D. Lagaros
المصدر: Buildings, Vol 12, Iss 3, p 296 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Building construction
مصطلحات موضوعية: CFT columns, sulfate damage, CFRP confinement, cyclic lateral loading, NLFEA, Building construction, TH1-9745
الوصف: It is rather costly and difficult to experimentally evaluate the performance of concrete-filled tubular (CFT) circular steel columns exposed to combined axial and cyclic lateral loads. This research paper uses the nonlinear finite element (NLFEA) technique to assess the influence of using carbon-fiber-reinforced polymer (CFRP) laminates on the structural response and failure mode of damaged-by-sulfate CFT circular steel columns. At the beginning, twenty-one CFT circular steel column models were devised and checked for soundness using the findings of previously conducted research. Next, the models were broadened to investigate how the models’ behavior was influenced by the CFRP number of layers and the level of sulfate damage. For experimental purposes, the numbers of CFRP layers were set to be zero, five, six, seven, eight, nine, and ten, while there were three levels of sulfate damage, namely: level 0 (undamaged), level 1 (73 days), and level 2 (123 days). Some of the models were left unconfined with CFRP wraps for comparison. The CFRP confinement was at the end of the models due to its importance regarding the models’ capacity of lateral load. The columns’ ends were confined to prevent the models from outward local buckling, which led to higher strength, bigger net drift, and enhanced energy dissipation. The NLFEA models were then appropriately modified and adjusted in accordance with credible previously conducted experimental research; after which, a parametric study was performed to investigate how the models’ behavior was affected by the number of CFRP layers and the level of axial load. The study found that the CFT circular steel column models’ performance significantly enhanced when the models were wrapped with five to ten CFRP layers. It must be mentioned, though, that using eight, nine, and ten CFRP layers gave almost similar results. In addition, the NLFEA results revealed that when the damaged-by-sulfate models were repaired externally with CFRP wraps, there was an improvement in the models’ cyclic behavior, as they showed a raise in the load capacity, an enhancement in the horizontal displacement, a greater displacement ductility, better energy dissipation, and little deterioration in secant stiffness. The study found that using wraps of CFRP proved a great efficiency with the change in the sulfate damage level.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2075-5309
Relation: https://www.mdpi.com/2075-5309/12/3/296; https://doaj.org/toc/2075-5309
DOI: 10.3390/buildings12030296
URL الوصول: https://doaj.org/article/eac7dd901f0040c48de6216cafa26f7d
رقم الأكسشن: edsdoj.7dd901f0040c48de6216cafa26f7d
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20755309
DOI:10.3390/buildings12030296