دورية أكاديمية

Stability and Thrombogenicity Analysis of Collagen/Carbon Nanotube Nanocomposite Coatings Using a Reversible Microfluidic Device

التفاصيل البيبلوغرافية
العنوان: Stability and Thrombogenicity Analysis of Collagen/Carbon Nanotube Nanocomposite Coatings Using a Reversible Microfluidic Device
المؤلفون: Kristina D. Popovich, Sergey A. Vagner, Denis T. Murashko, Galina N. Ten, Dmitry I. Ryabkin, Mikhail S. Savelyev, Evgeny P. Kitsyuk, Ekaterina A. Gerasimenko, Polina Edelbekova, Anton N. Konovalov, Dmitry V. Telyshev, Sergey V. Selishchev, Alexander Yu. Gerasimenko
المصدر: Membranes, Vol 13, Iss 4, p 403 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Chemical technology
LCC:Chemical engineering
مصطلحات موضوعية: nanocomposite, coating, microfluidic device, carbon nanotubes, collagen, thrombogenicity, Chemical technology, TP1-1185, Chemical engineering, TP155-156
الوصف: Currently, the development of stable and antithrombogenic coatings for cardiovascular implants is socially important. This is especially important for coatings exposed to high shear stress from flowing blood, such as those on ventricular assist devices. A method of layer-by-layer formation of nanocomposite coatings based on multi-walled carbon nanotubes (MWCNT) in a collagen matrix is proposed. A reversible microfluidic device with a wide range of flow shear stresses has been developed for hemodynamic experiments. The dependence of the resistance on the presence of a cross-linking agent for collagen chains in the composition of the coating was demonstrated. Optical profilometry determined that collagen/c-MWCNT and collagen/c-MWCNT/glutaraldehyde coatings obtained sufficiently high resistance to high shear stress flow. However, the collagen/c-MWCNT/glutaraldehyde coating was almost twice as resistant to a phosphate-buffered solution flow. A reversible microfluidic device made it possible to assess the level of thrombogenicity of the coatings by the level of blood albumin protein adhesion to the coatings. Raman spectroscopy demonstrated that the adhesion of albumin to collagen/c-MWCNT and collagen/c-MWCNT/glutaraldehyde coatings is 1.7 and 1.4 times lower than the adhesion of protein to a titanium surface, widely used for ventricular assist devices. Scanning electron microscopy and energy dispersive spectroscopy determined that blood protein was least detected on the collagen/c-MWCNT coating, which contained no cross-linking agent, including in comparison with the titanium surface. Thus, a reversible microfluidic device is suitable for preliminary testing of the resistance and thrombogenicity of various coatings and membranes, and nanocomposite coatings based on collagen and c-MWCNT are suitable candidates for the development of cardiovascular devices.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2077-0375
Relation: https://www.mdpi.com/2077-0375/13/4/403; https://doaj.org/toc/2077-0375
DOI: 10.3390/membranes13040403
URL الوصول: https://doaj.org/article/d7e70590d233494e880b9163a0dfea2c
رقم الأكسشن: edsdoj.7e70590d233494e880b9163a0dfea2c
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20770375
DOI:10.3390/membranes13040403