دورية أكاديمية

The Video Head Impulse Test and the Influence of Daily Use of Spectacles to Correct a Refractive Error

التفاصيل البيبلوغرافية
العنوان: The Video Head Impulse Test and the Influence of Daily Use of Spectacles to Correct a Refractive Error
المؤلفون: T.S. van Dooren, F.M.P. Lucieer, A.M.L. Janssen, H. Kingma, R. van de Berg
المصدر: Frontiers in Neurology, Vol 9 (2018)
بيانات النشر: Frontiers Media S.A., 2018.
سنة النشر: 2018
المجموعة: LCC:Neurology. Diseases of the nervous system
مصطلحات موضوعية: Video Head Impulse Test, Head Impulse Test, vestibulo-ocular reflex, VOR, refractive error, Diopter, Neurology. Diseases of the nervous system, RC346-429
الوصف: ObjectiveTo determine the influence of daily use of spectacles to correct a refractive error, on the vestibulo-ocular reflex (VOR) gain measured with the video head impulse test (vHIT).Study designThis prospective study enrolled subjects between 18 and 80 years old with and without a refractive error. Subjects were classified into three groups: (1) contact lenses, (2) spectacles, and (3) control group without visual impairment. Exclusion criteria comprised ophthalmic pathology, history of vestibular disorders, and alternated use of spectacles and contact lenses in daily life. Corrective spectacles were removed seconds before testing. One examiner performed all vHIT’s under standardized circumstances using the EyeSeeCam system. This system calculated the horizontal VOR gain for rightward and leftward head rotations separately.ResultsNo statistically significant difference was found in VOR gain between the control group (n = 16), spectacles group (n = 48), and contact lenses group (n = 15) (p = 0.111). Both the spectacles group and contact lenses group showed no statistically significant correlation between VOR gain and amount of refractive error, for rightwards (p = 0.071) and leftwards (p = 0.716) head rotations. There was no statistical significant difference in VOR gain between testing monocularly or binocularly (p = 0.132) and between testing with or without wearing contact lenses (p = 0.800).ConclusionIn this study, VOR gain was not influenced by wearing corrective spectacles or contact lenses on a daily basis. Based on this study, no corrective measures are necessary when performing the vHIT on subjects with a refractive error, regardless of the way of correction.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1664-2295
Relation: http://journal.frontiersin.org/article/10.3389/fneur.2018.00125/full; https://doaj.org/toc/1664-2295
DOI: 10.3389/fneur.2018.00125
URL الوصول: https://doaj.org/article/7f32bdb397c34258b6d9a294c125058f
رقم الأكسشن: edsdoj.7f32bdb397c34258b6d9a294c125058f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16642295
DOI:10.3389/fneur.2018.00125