Microbiological Evaluation of Water Used in Dental Units

التفاصيل البيبلوغرافية
العنوان: Microbiological Evaluation of Water Used in Dental Units
المؤلفون: Bartłomiej Błaszczyk, Magdalena Pajączkowska, Joanna Nowicka, Maria Szymonowicz, Wojciech Zakrzewski, Adam Lubojański, Marlena Hercuń-Jaskółka, Aleksandra Synowiec, Sebastian Fedorowicz, Wojciech Dobrzyński, Zbigniew Rybak, Maciej Dobrzyński
المصدر: Water, Vol 14, Iss 6, p 915 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Hydraulic engineering
LCC:Water supply for domestic and industrial purposes
مصطلحات موضوعية: dental unit waterline (DUWL), bacterial contamination, biofilm, water quality, Hydraulic engineering, TC1-978, Water supply for domestic and industrial purposes, TD201-500
الوصف: In modern dentistry, dental units are used for the treatment of patients’ teeth, and they need water to operate. Water circulates in a closed vessel system and finally reaches the mucous membranes of the patient as well as the dentist themselves. Therefore, the microbiological safety of this water should be a priority for physicians. This study aims to identify and determine the microbial count, expressed in CFU/mL, in water samples from various parts of the dental unit that are in direct contact with the patient. Thirty-four dental units located in dentistry rooms were analysed. The dentistry rooms were divided into three categories: surgical, conservative, and periodontal. It was found that in surgical rooms, the bacterial count was 1464.76 CFU/mL, and the most common bacterium was Staphylococcus pasteuri—23.88% of the total bacteria identified. In dentistry rooms where conservative treatments were applied, the average bacterial concentration was 8208.35 CFU/mL, and the most common bacterium was Ralsonia pickettii (26.31%). The periodontal rooms were also dominated by R. pickettii (45.13%), and the average bacterial concentration was 8743.08 CFU/mL. Fungi were also detected. Rhodotorula spp., Alternaria spp., and Candida parapsilosis were found to be the most common bacteria which are potentially harmful. This study indicates the need for effective decontamination of the water that is used in dental units and for constant monitoring of the level of contaminants present in the closed vessel system.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2073-4441
Relation: https://www.mdpi.com/2073-4441/14/6/915; https://doaj.org/toc/2073-4441
DOI: 10.3390/w14060915
URL الوصول: https://doaj.org/article/80879b693b204bb78b04f839082a1b66
رقم الأكسشن: edsdoj.80879b693b204bb78b04f839082a1b66
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20734441
DOI:10.3390/w14060915