دورية أكاديمية

Evaluation of stress distribution in and around dental implants using three different implant–abutment interfaces with platform-switched and non-platform-switched abutments: A three-dimensional finite element analysis

التفاصيل البيبلوغرافية
العنوان: Evaluation of stress distribution in and around dental implants using three different implant–abutment interfaces with platform-switched and non-platform-switched abutments: A three-dimensional finite element analysis
المؤلفون: Dipika Mitra, Prachi Gurav, Silvia Rodrigues, Bela Khobragade, Amruta Mahajan
المصدر: Journal of Dental Research, Dental Clinics, Dental Prospects, Vol 17, Iss 4, Pp 256-264 (2023)
بيانات النشر: Tabriz University of Medical Sciences, 2023.
سنة النشر: 2023
المجموعة: LCC:Dentistry
مصطلحات موضوعية: dental implants, dental implant abutment design, dental stress analysis, finite element analysis, Dentistry, RK1-715
الوصف: Background. A key factor for the success or failure of an implant is how the stresses are transferred to the surrounding bone. The implant‒abutment connection (IAC) is paramount for implant success. The purpose of this finite element analysis (FEA) study was to evaluate the stress distribution in and around three different implant‒abutment interfaces with platform-switched and platform-matched abutments using the finite element method (FEM). Methods. Three distinct types of IAC were selected: tri-channel internal connection, conical connection, and internal hex connection. Six models were generated, three in platform-switched and three in non-platform-switched configuration. Computer-Aided Three-Dimensional Interactive Application (CATIA) V5 R20 software was used to generate virtual models of the implants and the mandible. The models were transferred to Analysis of Systems (ANSYS) 15.0 software, in which the models were meshed and underwent FEA. Results. On the crestal bone, the highest von Mises stresses in platform-switched abutments were noticed in the internal hex implant‒abutment system (370 MPa), followed by the tri-channel implant‒abutment system (190 MPa) and conical implant‒abutment system (110 MPa). On the implant and the abutment screw, the highest von Mises stresses were observed in the internal hex implant‒abutment system, followed by the conical implant abutment system and tri-channel implant‒abutment system. Platform-switched implants had a more favorable stress distribution on crestal bone. Conclusion. Within the constraints of the current study, the internal hex connection exhibited the highest stress. In contrast, the conical abutment connection with platform switching configuration had more favorable stress distribution in crestal bone than other implant abutment systems.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2008-210X
2008-2118
Relation: https://joddd.tbzmed.ac.ir/PDF/joddd-17-256.pdf; https://doaj.org/toc/2008-210X; https://doaj.org/toc/2008-2118
DOI: 10.34172/joddd.2023.40723
URL الوصول: https://doaj.org/article/80899ce3afb1498482b13057e57d7458
رقم الأكسشن: edsdoj.80899ce3afb1498482b13057e57d7458
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2008210X
20082118
DOI:10.34172/joddd.2023.40723