دورية أكاديمية

Characterization of Odin-OSIRIS ozone profiles with the SAGE II dataset

التفاصيل البيبلوغرافية
العنوان: Characterization of Odin-OSIRIS ozone profiles with the SAGE II dataset
المؤلفون: C. Adams, A. E. Bourassa, A. F. Bathgate, C. A. McLinden, N. D. Lloyd, C. Z. Roth, E. J. Llewellyn, J. M. Zawodny, D. E. Flittner, G. L. Manney, W. H. Daffer, D. A. Degenstein
المصدر: Atmospheric Measurement Techniques, Vol 6, Iss 5, Pp 1447-1459 (2013)
بيانات النشر: Copernicus Publications, 2013.
سنة النشر: 2013
المجموعة: LCC:Environmental engineering
LCC:Earthwork. Foundations
مصطلحات موضوعية: Environmental engineering, TA170-171, Earthwork. Foundations, TA715-787
الوصف: The Optical Spectrograph and InfraRed Imaging System (OSIRIS) on board the Odin spacecraft has been taking limb-scattered measurements of ozone number density profiles from 2001–present. The Stratospheric Aerosol and Gas Experiment II (SAGE II) took solar occultation measurements of ozone number densities from 1984–2005 and has been used in many studies of long-term ozone trends. We present the characterization of OSIRIS SaskMART v5.0× against the new SAGE II v7.00 ozone profiles for 2001–2005, the period over which these two missions had overlap. This information can be used to merge OSIRIS with SAGE II into a single ozone record from 1984 to the present, if other satellite ozone measurements are included to account for gaps in the OSIRIS dataset in the winter hemisphere. Coincident measurement pairs were selected for ±1 h, ±1° latitude, and ±500 km. The absolute value of the resulting mean relative difference profile is R > 0.9 were calculated for 13.5–49.5 km, demonstrating excellent overall agreement between the two datasets. Coincidence criteria were relaxed to maximize the number of measurement pairs and the conditions under which measurements were taken. With the broad coincidence criteria, good agreement (< 5%) was observed under most conditions for 20.5–40.5 km. However, mean relative differences do exceed 5% for several cases. Above 50 km, differences between OSIRIS and SAGE II are partly attributed to the diurnal variation of ozone. OSIRIS data are biased high compared with SAGE II at 22.5 km, particularly at high latitudes. Dynamical coincidence criteria, using derived meteorological products, were also tested and yielded similar overall results, with slight improvements to the correlation at high latitudes. The OSIRIS optics temperature is low (
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1867-1381
1867-8548
Relation: http://www.atmos-meas-tech.net/6/1447/2013/amt-6-1447-2013.pdf; https://doaj.org/toc/1867-1381; https://doaj.org/toc/1867-8548
DOI: 10.5194/amt-6-1447-2013
URL الوصول: https://doaj.org/article/8452b469732243a3b222eaeba2494d8f
رقم الأكسشن: edsdoj.8452b469732243a3b222eaeba2494d8f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:18671381
18678548
DOI:10.5194/amt-6-1447-2013