Objective Evaluation of Pulse Width Using an Array Pulse Diagram

التفاصيل البيبلوغرافية
العنوان: Objective Evaluation of Pulse Width Using an Array Pulse Diagram
المؤلفون: Zi-Juan Bi PhD, Ji Cui PhD, Xing-Hua Yao PhD, Xiao-Juan Hu PhD, Si-Han Wang PhD, Meng-Chen Liang MRes, Zhi-Hui Zhou PhD, Jia-Tuo Xu PhD
المصدر: Journal of Evidence-Based Integrative Medicine, Vol 29 (2024)
بيانات النشر: SAGE Publishing, 2024.
سنة النشر: 2024
المجموعة: LCC:Other systems of medicine
LCC:Homeopathy
مصطلحات موضوعية: Other systems of medicine, RZ201-999, Homeopathy, RX1-681
الوصف: Background Pulse width, which can reflect qi , blood excess, and deficiency, has been used for diagnosing diseases and determining the prognosis in traditional Chinese medicine (TCM). This study aimed to devise an objective method to measure the pulse width based on an array pulse diagram for objective diagnosis. Methods The channel 6, the region wherein the pulse wave signal is the strongest, is located in the middle of the pulse sensor array and at the guan position of cunkou during data collection. Therefore, the main wave (h 1 ) time of the pulse wave was collected from the channel 6 through calculation. The left h 1 time was collected from the remaining 11 channels. The amplitudes at these time points were extracted as the h 1 amplitudes for each channel. However, the pulse width could not be calculated accurately at 12 points. Consequently, a bioharmonic spline interpolation algorithm was used to interpolate the h 1 amplitude data obtained from the horizontal and vertical points, yielding 651 (31 × 21) h 1 amplitude data. The 651 data points were converted into a heat map to intuitively calculate the pulse width. The pulse width was calculated by multiplying the number of grids on the vertical axis with the unit length of the grid. The pulse width was determined by TCM doctors to verify the pulse width measurement accuracy. Meanwhile, a color Doppler ultrasound examination of the volunteers’ radial arteries was performed and the intravascular meridian widths of the radial artery compared with the calculated pulse widths to determine the reliability. Results The pulse width determined using the maximal h 1 amplitude method was comparable with the radial artery intravascular meridian widths measured using color Doppler ultrasound. The h 1 amplitude was higher in the high blood pressure group and the pulse width was greater. Conclusions The pulse width determined using the maximal h 1 amplitude was objective and accurate. Comparison between the pulse widths of the normal and high blood pressure groups verified the reliability of the method.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2515-690X
2515690X
Relation: https://doaj.org/toc/2515-690X
DOI: 10.1177/2515690X241241859
URL الوصول: https://doaj.org/article/84569a5b9569406cb7a0a08183a90878
رقم الأكسشن: edsdoj.84569a5b9569406cb7a0a08183a90878
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2515690X
DOI:10.1177/2515690X241241859