Optimising effective parameters to improve performance quality in lateral flow immunoassay for detection of PBP2a in methicillin-resistant Staphylococcus aureus (MRSA)

التفاصيل البيبلوغرافية
العنوان: Optimising effective parameters to improve performance quality in lateral flow immunoassay for detection of PBP2a in methicillin-resistant Staphylococcus aureus (MRSA)
المؤلفون: M. Amini, M. R. Pourmand, R. Faridi-Majidi, M. Heiat, M. A. Mohammad Nezhady, M. Safari, F. Noorbakhsh, H. Baharifar
المصدر: Journal of Experimental Nanoscience, Vol 15, Iss 1, Pp 266-279 (2020)
بيانات النشر: Taylor & Francis Group, 2020.
سنة النشر: 2020
المجموعة: LCC:Materials of engineering and construction. Mechanics of materials
LCC:Chemical technology
مصطلحات موضوعية: lateral flow immunoassay, lfia, gold nanoparticles (aunp), rapid detection, pbp2a, mrsa, Materials of engineering and construction. Mechanics of materials, TA401-492, Chemical technology, TP1-1185
الوصف: Lateral flow immunoassay (LFIA) is the most widely used platform of the point-of-care (POC) detection. Since the most important factor in deciding the results of this technique is the visual quality of the test, it should be at its optimum. To address this issue, the present study examines optimising critical parameters to improve the quality of LFIA performance. In this regard the penicillin-binding protein 2a (PBP2a) in methicillin-resistant staphylococcus aureus (MRSA) was selected as a bacterial model. The targeted parameters included a) size of gold nanoparticles (AuNP), b) antibody conjugation conditions with AuNP, c) antibody concentrations in the capturing zones, d) the effects of blocking substances and different chemical buffers for pre-treatment of the strips. Visual quality of different manufactured strips revealed that the diameter of 14 ± 2, PH = 9.5 was the optimum for improvement of MRSA detection quality. The optimum concentration of labelling antibody in conjugate pad and concentration of the capturing antibody in the test band were 40 µg/ml and 1.1 µg/μl in PBS buffer (pH 7.4) respectively. In conclusion by finding the critical factors affecting the detection limit of lateral flow and optimising them, the visual quality of LFIA results can be increased.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1745-8080
1745-8099
17458080
Relation: https://doaj.org/toc/1745-8080; https://doaj.org/toc/1745-8099
DOI: 10.1080/17458080.2020.1775197
URL الوصول: https://doaj.org/article/858e5c45f30e4d15bdf9959eb79c5170
رقم الأكسشن: edsdoj.858e5c45f30e4d15bdf9959eb79c5170
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17458080
17458099
DOI:10.1080/17458080.2020.1775197