دورية أكاديمية

Hemodynamic effects of peri-operative statin therapy in on-pump cardiac surgery patients

التفاصيل البيبلوغرافية
العنوان: Hemodynamic effects of peri-operative statin therapy in on-pump cardiac surgery patients
المؤلفون: Hinz Jose, Gehoff Philipp, Schotola Hanna, Hosseini Morteza, Didilis Vassilios N, Jebran Ahmad, Gehoff Anastasia, Wiese Christoph H, Schulz Egbert, Schoendube Friedrich, Popov Aron
المصدر: Journal of Cardiothoracic Surgery, Vol 7, Iss 1, p 39 (2012)
بيانات النشر: BMC, 2012.
سنة النشر: 2012
المجموعة: LCC:Surgery
LCC:Anesthesiology
مصطلحات موضوعية: Cardiac surgery, Statin therapy, Hemodynamic, Outcome, Surgery, RD1-811, Anesthesiology, RD78.3-87.3
الوصف: Abstract Background Peri-operative statin therapy in cardiac surgery cases is reported to reduce the rate of mortality, stroke, postoperative atrial fibrillation, and systemic inflammation. Systemic inflammation could affect the hemodynamic parameters and stability. We set out to study the effect of statin therapy on perioperative hemodynamic parameters and its clinical outcome. Methods In a single center study from 2006 to 2007, peri-operative hemodynamic parameters of 478 patients, who underwent cardiac surgery with cardiopulmonary bypass, were measured. Patients were divided into those who received perioperative statin therapy (n = 276; statin group) and those who did not receive statin therapy (n = 202; no-statin group). The two groups were compared together using Kolmogorov-Smirnov-Test, Fisher’s-Exact-Test, and Student’s-T-test. A p value Results There was no significant difference in the preoperative risk factors. Onset of postoperative atrial fibrillation was not affected by statin therapy. Extended hemodynamic measurements revealed no significant difference between the two groups, apart from Systemic Vascular Resistance Index (SVRI) . The no-statin group had a significantly higher SVRI (882 ± 206 vs. 1050 ± 501 dyn s/cm5/m2, p = 0.022). Inotropic support was the same in both groups and no significant difference in the mortality rate was noticed. Also, hemodynamic parameters were not affected by different types and doses of statins. Conclusions Perioperative statin therapy for patients undergoing on-pump coronary bypass grafting or valvular surgery, does not affect the hemodynamic parameters and its clinical outcome.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1749-8090
Relation: http://www.cardiothoracicsurgery.org/content/7/1/39; https://doaj.org/toc/1749-8090
DOI: 10.1186/1749-8090-7-39
URL الوصول: https://doaj.org/article/85e257bfeedc4c8fac1c607091017fa2
رقم الأكسشن: edsdoj.85e257bfeedc4c8fac1c607091017fa2
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17498090
DOI:10.1186/1749-8090-7-39