دورية أكاديمية

Effective treatment of electrical storm by a wearable cardioverter defibrillator in a patient with severely impaired left ventricular function after myocardial infarction: a case report

التفاصيل البيبلوغرافية
العنوان: Effective treatment of electrical storm by a wearable cardioverter defibrillator in a patient with severely impaired left ventricular function after myocardial infarction: a case report
المؤلفون: Henrike Andresen, B. Sasko, D. Patschan, N. Pagonas, O. Ritter
المصدر: Journal of Medical Case Reports, Vol 15, Iss 1, Pp 1-7 (2021)
بيانات النشر: BMC, 2021.
سنة النشر: 2021
المجموعة: LCC:Medicine
مصطلحات موضوعية: Wearable cardioverter defibrillator, Ventricular tachycardia, Post-myocardial infarction, Electrical storm, Medicine
الوصف: Abstract Background The implantation of cardioverter defibrillators (ICDs) is an established therapy in the prevention of sudden cardiac death in patients with systolic dysfunction after myocardial infarction. To avoid immediate implantation of an ICD, wearable cardioverter defibrillator vests (WCD) can be used to protect patients against malignant rhythm disorders, while at the same time drug-based heart failure therapy has to be initiated. This drug therapy can improve left ventricular ejection fraction and primary prophylactic cardioverter defibrillator implantation may not be necessary. However, the recent Vest Prevention of Early Sudden Death Trial (VEST) questioned the regular use of the WCD in this setting. Case presentation A 47-year-old Caucasian man with severely impaired left ventricular function early after myocardial infarction was prescribed a WCD as primary prophylaxis to prevent sudden cardiac death. Seven days after the patient was supplied with a WCD, the patient suffered from an electrical storm with recurrent ventricular tachycardia (VT), which was successfully terminated 17 times by the WCD. On coronary angiography, the formerly infarct-related right coronary artery had TIMI (Thrombolysis in Myocardial Ischemia Trial) III flow, and a remaining stenosis in the left anterior descending artery (LAD) was stented, which did not stop recurrent VT. In the electrophysiology (EP) study, a focus was mapped in the left inferior ventricle, which was ablated. This stopped the VT. A second radio-frequency (RF) ablation in the same area was necessary after 14 days. Finally, a permanent cardioverter defibrillator was implanted. Conclusion We report the case of a patient who survived recurrent episodes of VT early after myocardial infarction by effective defibrillation with a WCD. The WCD is a useful device to bridge time until a final decision for implantation of a defibrillator.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1752-1947
Relation: https://doaj.org/toc/1752-1947
DOI: 10.1186/s13256-021-02833-2
URL الوصول: https://doaj.org/article/87548d1294f747bfaed33545d31a097f
رقم الأكسشن: edsdoj.87548d1294f747bfaed33545d31a097f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17521947
DOI:10.1186/s13256-021-02833-2